Skip to Main Content
AVEVA Product Feedback


ADD A NEW IDEA

All ideas

Showing 1354 of 1354

search for excluded attributes

Currently unable to search for excluded attributes in PSE's attribute search. Enable/allow this.
Matt Voll over 3 years ago in Asset Framework (AF) 0 No status

In a string builder DR, allow use of substituted values from non PI point DRs to retrieve an attribute value

If I have two AF databases, I would like to pull the value of an attribute from one database to another. The string builder path for the other database's attribute requires a value substitution from a non PI point DR from in the target AF DB (whic...
Guest over 3 years ago in Asset Framework (AF) 0 No status

Backup directly to AWS S3 bucket

We've successfully migrated our entire PI System into the AWS environment. Therefore it would be very nice if the pibackup.bat script would be able to directly backup to an S3 bucket.
Guest almost 2 years ago in Data Archive 1 No status

Use the AUDIT filegroup for all CDC tables

When enabling auditing, the default CDC tables are created within the ASSETS filegroup in SQL, while all replication tables are created in the AUDIT filegroup. It would be good if all CDC tables were in the AUDIT filegroup so that all of the audit...
Guest almost 2 years ago in Asset Framework (AF) 0 No status

Make "In" operator compatible with arrays within AF Analysis

We have many calculations following this basic pattern - take recorded values of one attribute, apply a filter (using FilterData), then retrieve values of a second attribute at the filtered timestamps of the first attribute. Currently, we cannot r...
Guest almost 2 years ago in Analytics & Calculations 0 No status

Overload the Convert function to allow a input UoM and output UoM for unitless values

For unitless values you can assign a unit of measure by using the Convert() function. To further convert this to another UoM in the same class you need to nest another Convert() function. For example, Convert(Convert(3600, "s"), "h")) It would sim...
Guest almost 2 years ago in Analytics & Calculations 0 No status

Pi Notifications should have smarts to exclude or N/A message body content for excluded attributes created from templates.

Pi Notifications should have smarts to exclude or N/A message body content for excluded attributes created from templates. Currently if we have say 4 attributes in an element template, and some instance elements have a couple of those "excluded", ...
Guest almost 2 years ago in Notifications 0 No status

Write Event Frame analysis outputs to attributes at the child level

We often write outputs at close to event frame attributes that reference a PI Point attribute on the referenced element. The analysis will not write to an EF attribute if it points to a referenced element attribute at the child level. In the examp...
Guest almost 2 years ago in Event Frames (EF) 0 No status

add-on for dataquality

Data scientists are 70% of their time busy with cleaning data. In the pi system, we can se lo and hi limits, but dataquality is more than that. It's also about consistent and continuous datarate, strange sensor signals,...Within Pi, this is still ...
Guest almost 2 years ago in Data Archive 0 No status

Password Protection For AF Databases

For AF databases we want to go beyond the AF security configuration and add password protection layer for databases.
Mohammed Qasim Asghar about 2 years ago in Asset Framework (AF) 0 No status