Skip to Main Content
AVEVA Product Feedback


ADD A NEW IDEA

All ideas

Make "In" operator compatible with arrays within AF Analysis

We have many calculations following this basic pattern - take recorded values of one attribute, apply a filter (using FilterData), then retrieve values of a second attribute at the filtered timestamps of the first attribute. Currently, we cannot r...
Guest over 2 years ago in Analytics & Calculations 0 No status

Overload the Convert function to allow a input UoM and output UoM for unitless values

For unitless values you can assign a unit of measure by using the Convert() function. To further convert this to another UoM in the same class you need to nest another Convert() function. For example, Convert(Convert(3600, "s"), "h")) It would sim...
Guest over 2 years ago in Analytics & Calculations 0 No status

Pi Notifications should have smarts to exclude or N/A message body content for excluded attributes created from templates.

Pi Notifications should have smarts to exclude or N/A message body content for excluded attributes created from templates. Currently if we have say 4 attributes in an element template, and some instance elements have a couple of those "excluded", ...
Guest over 2 years ago in Notifications 0 No status

Write Event Frame analysis outputs to attributes at the child level

We often write outputs at close to event frame attributes that reference a PI Point attribute on the referenced element. The analysis will not write to an EF attribute if it points to a referenced element attribute at the child level. In the examp...
Guest over 2 years ago in Event Frames (EF) 0 No status

add-on for dataquality

Data scientists are 70% of their time busy with cleaning data. In the pi system, we can se lo and hi limits, but dataquality is more than that. It's also about consistent and continuous datarate, strange sensor signals,...Within Pi, this is still ...
Guest over 2 years ago in Data Archive 0 No status

Password Protection For AF Databases

For AF databases we want to go beyond the AF security configuration and add password protection layer for databases.
Mohammed Qasim Asghar over 2 years ago in Asset Framework (AF) 0 No status

Ability to disable recalculation at the Database level in AF

Currently backfilling and recalculation are only enabled and disabled at the global and element level. There are instances where users of Asset Analytics, particularly when it comes to event frames, experience automatic recalculation upon a servic...
Guest over 2 years ago in Asset Framework (AF) 0 No status

Refrain from creating PI Points when AF Analytics is doing an expensive calcultion

If it can be known that the Analytics service is busy with an expensive calculation, the Data Archive should pause on creating PI Points, as this is also an expensive operation and may interfere with the calculation completion.
Laurie Dieffenbach almost 3 years ago in Analytics & Calculations 0 No status

Enable the compatibility of PI Builder with Microsoft 365/O365

With the existing versions, the PI Builder plugin doesn't work with O365 in its full capability. It would be great to have the compatibility setup from PI Builder plugin with MS365.
Guest almost 3 years ago in PI Builder 0 No status

Add a performance counter which can measure if Event frame reconciliation is performed correctly

Currently we only can tell an event frame reconciliation is performed by the green check after auto calculation, and it is not very easy to monitor. Since event frame usually use for alarms to operators. Accuracy is very important. We try to avoid...
Guest almost 3 years ago in Analytics & Calculations 0 No status