Check box option at attributes to handle PI tags that are bad and questionable

This suggestion is on how you manage the input tags into calculation that at some point it returned bad value (like I/O Timeout, Bad Input, Snapfix, etc...) or became questionable. These tags will make your calc at analysis become "Calc Failed". I...
Guest almost 4 years ago in Analytics & Calculations 0 No status

Extension of Rollup Scope without Excessive Computational Cost

If something I'll call lists are implemented following the model of categories (that is an element can belong to multiple, arbitrarily named entities) and rollup is extended to allow that as an option in addition to the parent element, this would ...
Guest almost 4 years ago in Analytics & Calculations 0 No status

Translate the descriptions of functions in PI System Explorer

See the attached picture. The picture also reveals other parts of PI System Explorer that are not translated. The picture and the idea for this suggestion come from https://pisquare.osisoft.com/s/feed/0D58W00006XNrBuSAL.
Guest almost 4 years ago in Analytics & Calculations 0 No status

Allow event scheduling for PI Point DR attributes that use RelativeTime or TimeRange

Currently it's not possible to use attributes that are based on a PI Point Data Reference with RelativeTime or TimeRange settings as triggers for analyses with event-triggered scheduling. You get the "No valid triggering inputs found" error. The r...
Guest almost 4 years ago in Analytics & Calculations 0 No status

Recorded Values Discrete Time Weighting

When using the recorded values function in Analysis, Time weighted totals and averages assumes that the data is continuous and not discrete. This creates issues with data streams that are both discrete and require time weighting functions. Ideally...
Guest almost 4 years ago in Analytics & Calculations 0 No status

Automatically apply Excel data validation to PI Builder columns

Currently, if there is a problem in the user's PI Builder sheet, the user will not know until they click on "Publish" and see the error messages. To help avoid this, consider having PI Builder apply Excel's data validation feature to columns that...
Guest almost 4 years ago in PI Builder 0 Declined

Include PI Server as a column option in PI Builder

A PI Server column would be a useful check to confirm which PI Server results are being published to, especially when a PI Admin has a drop down list of many PI Servers/Collectives.
Guest almost 4 years ago in PI Builder 1 Declined

Throw an error if both excdev and excdevpercent or both compdev and compdevpercent are present when publishing

Currently, if you publish a PI Point configuration that contains both excdev and excdevpercent or both compdev and compdevpercent, the "percent" versions silently take priority. This means that if a user imports excdev and excdevpercent, edits onl...
Guest almost 4 years ago in PI Builder 7 Declined

Use PI SQL Client for PI Builder data imports

PI Builder has a few problems: It is specific to Excel. It does not store data in tables. Imported data is static and can become outdated easily, which can lead to frequent imports, the need to publish PI Builder edits soon after import, and...
Guest almost 4 years ago in PI Builder 2 Declined

Give a more specific error message when publishing a span of 0

Currently, if you try to create/edit a PI Point to have a span of 0, an error message similar to the one below appears: Error occurred on line #, column #, while processing PI Data Archive 'PIDataArchive': [-38] Illegal Compression Deviation Speci...