Skip to Main Content
AVEVA Product Feedback


ADD A NEW IDEA

All ideas

Showing 849

Sizing sheet should include at least minimal support for AF Audit Trail

Currently there is not a single hint nor guidance on the impact of the Audit Trail in the sizing sheet, while the Audit Trail can have a major impact on the storage requirements.
Roger Palmen almost 3 years ago in System Management 0 No status

Align the Archive_AutoArchiveSize and Minimum Archive Size to be based on Tag Count, not Record Number Count

Schedule data archive shifts occur and create archive files based upon a Minimum Archive Size calculation. This calculation is based upon the total count of record numbers. When large amounts of tags are deleted, the total number of tags is reduce...
Guest almost 3 years ago in System Management 0 No status

Option to write Default Value to PI tags created through AF Templates

When creating PI points through AF Templates, there should be an option to "Write Default Value after Point Creation", or some other way to initialize the value of an automatically created PI tag. Right now, there is no way to replace the Pt Cre...
Guest almost 3 years ago in Asset Framework (AF) 3 No status

Convert should allow to override UOM

The introduction of the property "Delta UOM", made clear that when an incorrect UOM is set for an analysis result, there is no way (except casting to text and back to number) to change the UOM to a UOM of a different class. We need the convert fun...
Roger Palmen almost 3 years ago in Asset Framework (AF) 2 No status

Allow programmatic access to AF audit trail for report generation

As a PI admin I would like to be able to generate reports based on the AF audit trail.  Currently the audit trail can be accessed manually using the audit trail utility tool and manually output a file, though I would like to be able to query ...
Guest almost 3 years ago in Asset Framework (AF) 2 No status

Make AFDiag timeout based on AFService.exe.config settings

Make AFDiag timeout parameter based on AFService.exe.config settings instead of being hard coded.
Guest almost 3 years ago in Asset Framework (AF) 2 No status

Customized PI System Explorer view

Currently PI System Explorer views lots of stuff that is not used by most users (ports, models etc.) also, there are some things that may depend on decisions of particular client - for example, I don't want my users to use Formulas. I suggest to p...
Guest almost 3 years ago in Asset Framework (AF) 2 No status

AF enumeration sets should support values with the same name

The feature introduced in 2018 SP2 to manually synchronize digital state sets with AF enumeration sets has a limitation where state sets with duplicated names aren't imported correctly into AF. This is due to the current design of AF enumeration s...
Guest almost 3 years ago in Asset Framework (AF) 1 No status

Include AFDiag /AddIdentity functionality to PSE

Adding an identity to an established large system can cause a flood of change records, leading to performance issues. The AFDiag /AddIdentity feature will bypass this issue, but it would be more convenient to have this functionality included in PSE.
Guest almost 3 years ago in Asset Framework (AF) 2 No status

Create a TriggeredOn() function for PI Analysis

The TriggeredOn() function would return true if the inserted attribute was the reason for the expression analysis to trigger/evaluate. I have multiple attributes in the same analysis but only want each line to have an output when its corresponding...
Guest 6 months ago in Analytics & Calculations 0 No status