Skip to Main Content
AVEVA Product Feedback


ADD A NEW IDEA

All ideas

Showing 453

Relative time in PI AF being DST-Aware

When utilizing the output timestamp relative to trigger time functionality within PI AF 2018, customer has experienced an issue where values written 12 hours before (*-12h) (ideally at 12PM/12AM, thanks to a 12 hour period) the output time will wr...
Guest over 2 years ago in Analytics & Calculations 5 Declined

Add child attributes to Intellisense pop-up list for analyses

Child attributes of attributes on an element do not appear in Intellisense menu when configuring analyses in AF.
Guest over 2 years ago in Analytics & Calculations 0 Declined

Filtered calculation in PI ProcessBook

In PI Calcs inside PI ProcessBook or even PI AF, the could be a way of filtering calculations, such as the following 1. Tag VALUE stores a process value 2. Tag STATUS stores the asset status We want to determine how long VALUE was higher than a ...
Guest over 2 years ago in Analytics & Calculations 0 Declined

Allow functions such as RecordedValues to be used when all mapped outputs are not configured to save output history.

There are many instances where I do not want to save mapped outputs of PI Analyses to PI tags, but would like to use certain functions that can only be used when this is done.
Guest over 2 years ago in Analytics & Calculations 0 Declined

PI Analysis and PI Notifications in HA

Please allow PI Analysis and PI Notifications to work in an HA setup or in a NLB such as the AF HA recommended scenario. At present the only similar configuration is a failover in a Windows Cluster which TS can't confirm its stability with a NLB p...
Guest over 2 years ago in Analytics & Calculations 1 Declined

Automatically apply Excel data validation to PI Builder columns

Currently, if there is a problem in the user's PI Builder sheet, the user will not know until they click on "Publish" and see the error messages. To help avoid this, consider having PI Builder apply Excel's data validation feature to columns that...
Guest over 2 years ago in PI Builder 0 Declined

Include PI Server as a column option in PI Builder

A PI Server column would be a useful check to confirm which PI Server results are being published to, especially when a PI Admin has a drop down list of many PI Servers/Collectives.
Guest over 2 years ago in PI Builder 1 Declined

Throw an error if both excdev and excdevpercent or both compdev and compdevpercent are present when publishing

Currently, if you publish a PI Point configuration that contains both excdev and excdevpercent or both compdev and compdevpercent, the "percent" versions silently take priority. This means that if a user imports excdev and excdevpercent, edits onl...
Guest over 2 years ago in PI Builder 7 Declined

Use PI SQL Client OLEDB for PI Builder data imports

PI Builder has a few problems: It is specific to Excel. It does not store data in tables. Imported data is static and can become outdated easily, which can lead to frequent imports, the need to publish PI Builder edits soon after import, and the r...
Guest over 2 years ago in PI Builder 2 Declined

Give a more specific error message when publishing a span of 0

Currently, if you try to create/edit a PI Point to have a span of 0, an error message similar to the one below appears: Error occurred on line #, column #, while processing PI Data Archive 'PIDataArchive': [-38] Illegal Compression Deviation Speci...
Guest over 2 years ago in PI Builder 0 Declined