Negative numbers in digitalsets

Negative numbers in digitalsets for all PI interface and skip numbers, basically that the digitalset is like the enum of AF
Guest almost 4 years ago in Data Archive 1 No status

Analysis Preview Results - Remove Table and Graph

When using the preview analysis function an an analysis with many variables the preview graph and table struggles to keep up, and uses a long time to update. When there are many variables, these are also quite useless. It would therefore be an i...
Guest almost 4 years ago in Analytics & Calculations 2 Declined

Logic for SQC calculations

I would like the ability to flag an SQC event only if I am in a batch, on a grade run, or in some other process condition. Right now, I am getting an SQC outside control limit when my phase is "inactive." Let there be more configuration of this in...
Guest almost 4 years ago in Analytics & Calculations 0 No status

Analysis service should not close opened EF when last evaluation time is exceeds MaximumAllowedAutoBackfillingSpanInHours

As PI server administrator I would like that when the Analysis service is restarted with autobackfilling enabled, if there are any EF analysis where last evaluation time is older than *-MaximumAllowedAutoBackfillingSpanInHours, EFs that are opened...
Guest almost 4 years ago in Analytics & Calculations 0 No status

Filter/Flag PI System Generated Error Message as Analysis Inputs to prevent False Positive Evaluations

The PI data archive (and potentially other systems) can generate many automated error messages to assist with troubleshooting. One such key example is "[-10767] Client exceeded maximum concurrent queries in RPC thread pool", which occurs when a se...
Guest almost 4 years ago in Analytics & Calculations 0 No status

PI Analysis and PI Notifications in HA

Please allow PI Analysis and PI Notifications to work in an HA setup or in a NLB such as the AF HA recommended scenario. At present the only similar configuration is a failover in a Windows Cluster which TS can't confirm its stability with a NLB p...
Guest almost 4 years ago in Analytics & Calculations 1 Declined

Improve Scalability of PI Analytics

Currently you can only run a single PI Analytics instance at a time. We have two VMs running PI Analytics in a failover situation, but this means that one of the VMs is sitting idle 99% of the time. We are starting to hit the limits of scaling w...
Guest almost 4 years ago in Analytics & Calculations 0 No status

Abililty to minimise Preview result window

When you develop an expression it is very useful to use the preview function. Quite often you can discover and debug directly from this, but you are not abel to close down the window and check the code! So either you memorise or you export the cs...
Guest almost 4 years ago in Analytics & Calculations 0 No status

Limit visibility of EF to those of which the user has read access to the primary element

Currently the visibility of Event Frames in PI Vision and elsewhere is only limited by the security of those Event Frames. As the security of Event Frames created by Analyses is dependent on the security settings of the Event Frame template (and t...
Christoph Rose almost 4 years ago in Event Frames (EF) 2 No status

Automatic Event Frame Name Reevaluation

I would like to see an option on an event frame generation analysis, probably under advanced event frame settings, that enables automatic event frame name reevaluation at the end time of the generated event frame. Right now I have event frame gene...
Guest almost 4 years ago in Event Frames (EF) 0 No status