Add alternatives to reset Active Directory Properties in AF

Please add more ways to reset, or modify, the Active Directory Properties in AF, to be able to search for contacts, as currently the only ways are through PSE and by using AF SDK code. If those properties are misconfigured or the account used is m...
Daniel Füeß Soares 11 months ago in Asset Framework (AF) 0 No status

Link to user manual/ help file unavailable from UI

The connector UI does not contain any link to the help documentation or the user manual. The files are also not found in the standard PIPC path and are available only with the installation extarction
Guest about 3 years ago in Installation 0 No status

Allow individual MSIs to be extracted from the PI Server 2018 install kit

(from case 939560) I kindly request you add an enhancement request to allow individual MSIs to be extracted from the install kit. On numerous occasions, I’ve had upgrade/install failures that could be easily overcome by re-running the affected MS...
Guest about 3 years ago in Installation 4 Declined

Improve AF Transformer PostProcessing logging and performance

PostProcessing stage of the transformation (if using ParantID and ElementID) should use paging (or another approach) for a better performance, it should also be better logged and display number of objects processed, a number of objects in the list...
Guest about 3 years ago in General 0 Declined

Include a "Disable" option for Table Connections

Linked Tables can cause bad behaviors (freezes; attributes waiting for values) in PI System Explorer when the password supplied is no longer valid. The solution is to update the password, or delete the Table Connection if the new password isn't av...
Guest about 3 years ago in General 0 No status

As a PI Administrator, we should be able to see which PI mapping was used for a Windows AD user in PI message logs.

Through PI message logs I want to see which PI mapping was used for a Windows AD user, currently only the PI identity associated the windows AD is visible in the Logs. PI mapping information will give us more idea/facts about the particular Window...
Guest about 3 years ago in Data Archive 1 No status

Allow bi-temporal data archiving

PI DA Server should allow for more flexibility in terms of the format of archived data. A big advantage would be if PI could archive two timestamps per event. One timestamp will come from whatever the data source is (PI Interfaces, fiels devices, ...
Guest about 3 years ago in Data Archive 2 Declined

Thresholds for PI Points

It would be nice to have threshold attributes for pi points. Then we could configure that values received from the source outside this limits would be ignored (not stored), substituted by the respective threshold value or even by an "Over\Under Ra...
Guest about 3 years ago in Data Archive 2 Declined

Event mode that applies NoReplace to snapshot as well

Currently the NoReplace event mode will Append data if a value with the same timestamp as the snapshot comes in. Customer would like an event mode that would discard the value if there is existing data with the same timestamp regardless of the val...
Guest about 3 years ago in Data Archive 1 No status

Method to backup and restore PI Points only

The PI backup tools currently do not have a method to backup only the files related to PI Points. The purpose of this would be to refresh the point table on a QA system from a production system. The current PI backup method is all or nothing.
Guest about 3 years ago in Data Archive 0 No status