Skip to Main Content
AVEVA Product Feedback


ADD A NEW IDEA

All ideas

Showing 1331 of 1331

As a PI Administrator, we should be able to see which PI mapping was used for a Windows AD user in PI message logs.

Through PI message logs I want to see which PI mapping was used for a Windows AD user, currently only the PI identity associated the windows AD is visible in the Logs. PI mapping information will give us more idea/facts about the particular Window...
Guest almost 3 years ago in Data Archive 1 No status

Allow bi-temporal data archiving

PI DA Server should allow for more flexibility in terms of the format of archived data. A big advantage would be if PI could archive two timestamps per event. One timestamp will come from whatever the data source is (PI Interfaces, fiels devices, ...
Guest almost 3 years ago in Data Archive 2 Declined

Thresholds for PI Points

It would be nice to have threshold attributes for pi points. Then we could configure that values received from the source outside this limits would be ignored (not stored), substituted by the respective threshold value or even by an "Over\Under Ra...
Guest almost 3 years ago in Data Archive 2 Declined

Event mode that applies NoReplace to snapshot as well

Currently the NoReplace event mode will Append data if a value with the same timestamp as the snapshot comes in. Customer would like an event mode that would discard the value if there is existing data with the same timestamp regardless of the val...
Guest almost 3 years ago in Data Archive 1 No status

Method to backup and restore PI Points only

The PI backup tools currently do not have a method to backup only the files related to PI Points. The purpose of this would be to refresh the point table on a QA system from a production system. The current PI backup method is all or nothing.
Guest almost 3 years ago in Data Archive 0 No status

Negative numbers in digitalsets

Negative numbers in digitalsets for all PI interface and skip numbers, basically that the digitalset is like the enum of AF
Guest almost 3 years ago in Data Archive 1 No status

Analysis Preview Results - Remove Table and Graph

When using the preview analysis function an an analysis with many variables the preview graph and table struggles to keep up, and uses a long time to update. When there are many variables, these are also quite useless. It would therefore be an i...
Guest almost 3 years ago in Analytics & Calculations 2 Declined

Logic for SQC calculations

I would like the ability to flag an SQC event only if I am in a batch, on a grade run, or in some other process condition. Right now, I am getting an SQC outside control limit when my phase is "inactive." Let there be more configuration of this in...
Guest almost 3 years ago in Analytics & Calculations 0 No status

Have PI Analysis Service Automatically Update the Definition of Existing Digital States

If an existing digital state is edited, PI Analysis Service does not recognize the change until it is restarted. A digital state should not be edited too often. However, it would be useful if there is a process to update cache, including each digi...
Guest almost 3 years ago in Analytics & Calculations 0 No status

Analysis service should not close opened EF when last evaluation time is exceeds MaximumAllowedAutoBackfillingSpanInHours

As PI server administrator I would like that when the Analysis service is restarted with autobackfilling enabled, if there are any EF analysis where last evaluation time is older than *-MaximumAllowedAutoBackfillingSpanInHours, EFs that are opened...
Guest almost 3 years ago in Analytics & Calculations 0 No status