Create substitution parameter for parent of referenced element

I would like to be able to reference the parent of a element reference. As it currently stands, it is only possible to reference the original parent element of an element.
Guest over 2 years ago in Asset Framework (AF) 1 No status

Higher Cache Time for PIEFGEN

A higher Cache time for the PI EFGEN would be great. Currently the limit ist 60 days.
Guest 11 months ago in Event Frames (EF) 0 No status

Ability to define if an analysis will be inherited from a base template.

I would like to easily define if a derived template will inherit an analysis. This derived template should have a check box on the analysis that says: 'Do not Inherent'. Without this option I have to disable the analyses mapped to the derived temp...
Guest almost 2 years ago in Asset Framework (AF) 0 No status

Backup directly to AWS S3 bucket

We've successfully migrated our entire PI System into the AWS environment. Therefore it would be very nice if the pibackup.bat script would be able to directly backup to an S3 bucket.
Guest 11 months ago in Data Archive 1 No status

Export Multiple Audit Logs into one XML/TXT File

The pidiag -xa utility doesn't support selecting a folder location and exporting the contents to a single XML/TXT file. This would be very helpful for bulk auditing actions.
Guest almost 2 years ago in Data Archive 1 No status

Use the AUDIT filegroup for all CDC tables

When enabling auditing, the default CDC tables are created within the ASSETS filegroup in SQL, while all replication tables are created in the AUDIT filegroup. It would be good if all CDC tables were in the AUDIT filegroup so that all of the audit...
Guest 12 months ago in Asset Framework (AF) 0 No status

Make "In" operator compatible with arrays within AF Analysis

We have many calculations following this basic pattern - take recorded values of one attribute, apply a filter (using FilterData), then retrieve values of a second attribute at the filtered timestamps of the first attribute. Currently, we cannot r...
Guest 12 months ago in Analytics & Calculations 0 No status

Overload the Convert function to allow a input UoM and output UoM for unitless values

For unitless values you can assign a unit of measure by using the Convert() function. To further convert this to another UoM in the same class you need to nest another Convert() function. For example, Convert(Convert(3600, "s"), "h")) It would sim...
Guest 12 months ago in Analytics & Calculations 0 No status

Pi Notifications should have smarts to exclude or N/A message body content for excluded attributes created from templates.

Pi Notifications should have smarts to exclude or N/A message body content for excluded attributes created from templates. Currently if we have say 4 attributes in an element template, and some instance elements have a couple of those "excluded", ...
Guest about 1 year ago in Notifications 0 No status

Write Event Frame analysis outputs to attributes at the child level

We often write outputs at close to event frame attributes that reference a PI Point attribute on the referenced element. The analysis will not write to an EF attribute if it points to a referenced element attribute at the child level. In the examp...
Guest about 1 year ago in Event Frames (EF) 0 No status