Powershell PIArchive.Reprocess

A powershell method for reprocessing PI Archve Files. $myPIArchive = Get-PIArchiveFileInfo -Connection $myPi -Name "someArchiveFile" $myPIArchive.ReprocessArchive -NewFileName $false|"filename" -Type Dynamic|Fixed -OtherCoolOptions Reading data...
Guest over 2 years ago in Data Archive 1 Completed

PI Analysis: Auto-backfill should not skip analyses - ones that hasn't had an new value in a while (72+hrs)

Whenever the PI Analysis Service is restarted, the auto-backfill feature (if enabled) kicks in, and backfills any gaps from the downtime. However, the analysis service will not auto-backfill analyses that haven't been updated in the last 72 hours...
Guest over 2 years ago in Analytics & Calculations 9 Completed

Notification e-mail delivery channel to accept multiple email address in a single enpoint

In AF Service 2017 R2, Notification no longer supports multiple e-mail addresses delimited by comma (,) or semicolon (;) to be added in a single delivery endpoint. If we do so, it will only send an e-mail only to the first recipient. The workarou...
Guest over 2 years ago in Analytics & Calculations 1 Completed

Delayed Triggers for Analytics

We have some data analyzers in the DCS system that provide results to PI tags in a delayed fashion. Sample use case: (t+0s) valve closes, (t+30s) measurement1 sent to the DCS tag m1 (t+60s) measurement2 sent to the DCS tag m2. We need to tri...
Guest over 2 years ago in Analytics & Calculations 2 Completed

Event Frame Generation for Step Changes

There does not seem to be a clear and concise way to trigger a new event frame (and end an old one) based on a step change in a tag. For example, if we had a tag, PHASE, that changed every time we entered a  new phase and remained at that val...
Guest over 2 years ago in Event Frames (EF) 3 Completed

Edit Notify Option in bulk

They want to know if it is possible to set the Subscriber Notify Option as Event start and End as default in the new PI Notifications Rules They claim it is hard to set it for all the subscribers one by one. There is currently no way to do that ...
Guest over 2 years ago in Notifications 3 Completed

Configurable default Attribute ConfigString

Right now, when you create an attribute in a template and assign it a Data Reference of PI Point, it defaults to a ConfigString of "\\%Server%\%Attribute%". %Server% has some known administrative headaches because what it populates as is dependent...
Guest over 2 years ago in Asset Framework (AF) 2 Completed

AF Analytics overwrites data in real time

Current AF analytics cannot overwrite data in real time, only appends new value with the same timestamp.
Guest over 2 years ago in Analytics & Calculations 1 Completed

Include root cause data into Notifications message

Include event frames root cause data into Notifications message. A customer ask about how to include event frames root cause data into notifications message because he has a notification message generated when an equipment fails but to diagnose th...
Guest over 2 years ago in Notifications 0 Completed

Future Plans for Notifications High Availability?

General Query: What are the future plans for High Availability of PI Notifications. To my understanding, the only option providing seamless failover is to utilise a Windows Server Failover Cluster, with high performance Shared Storage to hold th...
Guest over 2 years ago in Notifications 2 Completed