Skip to Main Content
AVEVA Product Feedback


ADD A NEW IDEA

All ideas

Showing 830

Reduce Search Performance Variability when identical filters are used but return result sets of varying size

Currently, the AF Server will produce identical parameterized SQL queries for 2 AF Searches that search for the same object type with the same filters. On a large system, performing a search that produces a small result set can cause SQL Server to...
Guest about 2 years ago in Asset Framework (AF) 0 No status

Option to specify the a EF Snapshot value with a specific Offset

We would like to configure a snapshot value in a EF for e.g. +10min and +20min after the EF start. Currently this is not possible with the EF Data value retrivial methods Refered Case is #01074855
Guest about 2 years ago in Event Frames (EF) 0 No status

Allow event creation without populating in PI Vision Event Table

I use PI Vision Event Tables to monitor real-time events, but I also want to be able to create events for data analytics but I do want to see ever occurrence that even in the PI Vision events table. I would like the ability, when events are create...
Guest about 2 years ago in Asset Framework (AF) 0 No status

Expose AF Analytics performance statistics for notifications

The new statistics exposed in PI System Explorer in 2022 are helpful, but the next step should be exposing that information in a way that customers could actively monitor it and send proactive alerts. For example, this could include functionality ...
Laurie Dieffenbach about 2 years ago in Analytics & Calculations 0 No status

Assign and deny security privileges on PI AF Saved Libraries

As a PI AF Administrator, I would like to assign and deny the privileges to read, create, update and delete PI AF Saved Libraries. Currently, securable objects do not include PI AF Saved Libraries.
Guest about 2 years ago in Asset Framework (AF) 0 No status

Audible Alerts for Multi-State Objects

I would like to be able to add an audible alert to a multi-state object, where once a tag reaches a user specified value, it would trigger an audible alert on that computer.
Guest about 2 years ago in General 0 No status

Add a counter to stale\Bad tags window

In point builder, the number of tags you are working on is displayed in the top right corner. I'd like to suggest the same on the stale tags window. Why? I do systems administration on 380 controls machines across 68 power plants. Of those 380 mac...
Guest over 2 years ago in System Management 0 No status

Add steam specific heat functions

Steam specific heat is useful in advanced analytics to monitor control valve performance. Isobaric and isochoric specific heat functions are a part of the 1997 IAPWS IF as are the rest of the steam functions already included.
Guest over 2 years ago in Analytics & Calculations 0 No status

PI AF extract parameters from a tag to include them in AF attributes

I would like to be able to define an af Attribute that is a parameter of a tag. For example pointsource, in order to test a writing.
Guest over 2 years ago in Asset Framework (AF) 0 No status

Table Lookup Enumeration

Similar to Enumeration Sets, have a drop-down displaying the options but allow for a Table Lookup Query to display the distinct values for a column.
Guest over 2 years ago in Asset Framework (AF) 0 No status