Skip to Main Content
AVEVA Product Feedback


ADD A NEW IDEA

All ideas

Showing 842

Subscription Templates

I'm currently working on a project to push notifications immediately to a database, via REST delivery endpoint. However, each delivery endpoint needs to be subscribed per notification rule, AND also configured. Configuration can take awhile to do,...
Guest about 2 years ago in Notifications 0 No status

Export Identities, Users & Groups to CSV instead of XML files

Since PI SMT cannot import XML files to fetch the PI Identities, Users & Groups from a different PI Server, it would be useful to have it export this information to a CSV file instead, which can be used by different tools to insert them back i...
Guest about 2 years ago in General 0 No status

Deleting a root element can leave orphaned child elements in the AFDatabase

https://customers.osisoft.com/s/knowledgearticle?knowledgeArticleUrl=169E3AE1-F716-0842-B0FE-9F4563316373 Deleting a root element can leave orphaned child elements in the AFDatabase Please review the KB article. This scenario should not be allowed...
Guest about 2 years ago in Asset Framework (AF) 0 No status

PIvision Error check

Regarding the PIVision screen, I would like to ask about the error that PIPoint or attribute cannot be referenced correctly. I would like to have a function that can extract the screen name that is an error at once. There are a lot of screens and ...
Guest about 2 years ago in Asset Framework (AF) 0 No status

Reduce Search Performance Variability when identical filters are used but return result sets of varying size

Currently, the AF Server will produce identical parameterized SQL queries for 2 AF Searches that search for the same object type with the same filters. On a large system, performing a search that produces a small result set can cause SQL Server to...
Guest about 2 years ago in Asset Framework (AF) 0 No status

Option to specify the a EF Snapshot value with a specific Offset

We would like to configure a snapshot value in a EF for e.g. +10min and +20min after the EF start. Currently this is not possible with the EF Data value retrivial methods Refered Case is #01074855
Guest about 2 years ago in Event Frames (EF) 0 No status

Allow event creation without populating in PI Vision Event Table

I use PI Vision Event Tables to monitor real-time events, but I also want to be able to create events for data analytics but I do want to see ever occurrence that even in the PI Vision events table. I would like the ability, when events are create...
Guest over 2 years ago in Asset Framework (AF) 0 No status

Expose AF Analytics performance statistics for notifications

The new statistics exposed in PI System Explorer in 2022 are helpful, but the next step should be exposing that information in a way that customers could actively monitor it and send proactive alerts. For example, this could include functionality ...
Laurie Dieffenbach over 2 years ago in Analytics & Calculations 0 No status

Assign and deny security privileges on PI AF Saved Libraries

As a PI AF Administrator, I would like to assign and deny the privileges to read, create, update and delete PI AF Saved Libraries. Currently, securable objects do not include PI AF Saved Libraries.
Guest over 2 years ago in Asset Framework (AF) 0 No status

Add a counter to stale\Bad tags window

In point builder, the number of tags you are working on is displayed in the top right corner. I'd like to suggest the same on the stale tags window. Why? I do systems administration on 380 controls machines across 68 power plants. Of those 380 mac...
Guest over 2 years ago in System Management 0 No status