The feature added in 2017 R2 was for authentication of the SOAP payload, not for managing headers within the payload. PI remains unusable as a secure source of data for Maximo without it because you can't configure a MAXAUTH header.
There's...
Guest
almost 3 years ago
in Notifications
4
No status
Allow changes to pitimeout table (tuning parameters) to be audited
I can be helpful when tracking down issues or troubleshooting past events what the values of tuning parameters were at a given time. Adding the ability to Audit this table would allow retrospective insight into tuning parameter configurations.
A ...
As an AF administrator, I would like to send in an attachment of a Notification files that are specified by file path in AF attributes. I currently do this by specifying the value at start time of an AF attribute that contains the changing f...
Guest
almost 3 years ago
in Notifications
0
No status
Allow Default Attribute to use inherited attributes
Derived templates (element and event frame) will not allow for inherited attributes to be used as the "Default Attribute". This breaks inherited analyses that use the "Default Attribute". The only workaround is to override the the attribute, which...
As a PI user, I want to be able to visualize and analyze the SQC violations that are generated by the SQC rules.
The ability to save SQC outputs such as Mean, median, mode, stdev, Cpk, max, min, 1-5 sigma zones, ucl, lcl in the follo...
Ability to clear and not send notifications on Notification service startup.
We've had issue with Notifications spamming users with events should a PI collective member stop getting data.
At times, we need to disable the notification service until we can resolve the issue. After the issue is resolved, we need to start th...
Guest
almost 3 years ago
in Notifications
10
No status
Use Case: calculating which Shift is working within a rotating-shift cycle, which must the follow Daylight Savings Time offset.
This function is available in the Performance Equation library, but not in AF. The function itself is simple once one ...
Order by name (alphanumerically) the Analysis in the Management tab in PI System Explorer
I would like to be able to order by name (alphanumerically) the Analysis in the Management tab in PI System Explorer after retrieving a list of analyses through a search/filtering. This could be done by clicking on the Name column.
Limit Analytics to Only Write to Specific Pointsource
A useful setting for PI Analytics would be the ability to specify a specific pointsource that the Analytic service writes to. This would help tremendously to troubleshoot what tags on the PI DA server are being written to by AF Analytics.