Skip to Main Content
AVEVA Product Feedback


ADD A NEW IDEA

All ideas

Showing 1338 of 1338

Store event frame start and end time as DateTime to allow sub-millisecond duration event frames

Because event frame start and end time are stored as a bigint datatype in PIFD.dbo.AFEventFrame, the precision only seems to be to the nearest millisecond. This is a problem for sub-millisecond event frames. Why aren't event frame start and end ti...
Guest about 3 years ago in Event Frames (EF) 3 No status

Add an Annotations column to the Event Frames search window

It would be nice to add an Annotations column to the search page of Event Frames, so that I can better analyze them directly from PSE for administration purposes
Guest about 3 years ago in Event Frames (EF) 0 No status

Keeping old events that have been manually worked on in case of Recalculation/Backfill

Case 1. There are some EFs that should be acknowledged and commented by equipment owners. In Pharma World, these comments qualify as GxP and shall not be deleted. Whereas Event Frames generated by analysis can sometimes due to data coming late or ...
Guest about 3 years ago in Event Frames (EF) 1 No status

End first child event frame when StartTrigger condition no longer is fulfilled

Currently child event frames are only created when the following applies: + There's an End Trigger + There's a second Start Trigger that takes over Unlike later child event frames, the first one will not end simply because its own Start Trigger c...
Guest about 3 years ago in Event Frames (EF) 1 No status

Option to write EF template attribute result back into a PI-tag

Creating a possibility to populate PI-tag's based on the Events. These PI-tag's can be used in reports/displays. Generating batch, daily, hourly, shift and other "event" driven values and store them in a specific PI-tags would very easy and may re...
Guest about 3 years ago in Event Frames (EF) 1 No status

Change Event Frame Analysis Category of the Specific Element

If I have an element template with event frame analyses and notifications, I might want to change the event frame analysis category of a specific element. I thought this could be done by selecting “Allow Extensions” for the element template, but I...
Guest about 3 years ago in Notifications 1 No status

Give users the option to search existing Notification Contact Groups

In the "Contacts" pane, allow users to search through existing Notification Contact Groups. Additionally, give users the option to organize contact groups in some way, either by who created the group or by extending AF Categories to the contacts p...
Guest about 3 years ago in Notifications 0 No status

Allow Event Frame Variable values to be used in a Notification Rule email

I have a scenario where we are sending alerts on how well a fermentation batch has performed. I need look at attribute values at a specified timestamp and compare the other values at that same time. Easy enough right? The problem is I cannot send ...
Guest about 3 years ago in Notifications 1 Declined

Provide option for backfilling history and details within notification email

The Notifications rules email format should include backfilling history and details of its respective event frame in the content options. The backfilling content can include: - Completed Time - Start Time - End Time - Last Evaluation - Events...
Guest about 3 years ago in Notifications 5 Declined

Resend Interval value inside an attribute

As a PI System Administrator, I want to set the Resend Interval at an attribute so I do not have to enter every time at the notification and take some time to change it. From time to time we have different priority levels on our equipment that n...
Guest about 3 years ago in Notifications 0 Declined