To take full advantage of AF and substitution parameters it would be great to have a sort of type ID. Now i have to rename all tags to gain this possibility. It would be easy if i could use a portion of the tag name and a type id. Then i cou...
Guest
about 4 years ago
in Data Archive
3
Tell us more
I have a particular application for storing partial discharge events into the PI Server. Many of the events are at the same timestamp, which result in multiple events at the same time.
Guest
about 4 years ago
in Data Archive
1
Declined
Allow edited default tag attributes to be used in Point Builder SMT Plugin
Currently there is a procedure that allows using piconfig to Change Default Tag Attributes however these changes do not impact the defaults of tags created through Point Builder plugin within SMT but works on other clients that allow tag creation ...
Guest
about 4 years ago
in Data Archive
0
No status
Currently, there are two methods to 'shift' archives:
1. "Archive_AutoArchiveFileRoot" set to blank
2. "Archive_OverwriteDataOnAutoShiftFailure" enabled
Neither method shifts to dynamic archives. We have three sites that merged PI servers, thus ha...
Pete Long
about 4 years ago
in Data Archive
1
No status
Preserve variable-attribute mapping upon attribute path change
Currently, if a variable is mapped to an attribute and the attribute's AF path changes, the variable must be remapped to the attribute.
Instead of relying on the attribute's full path to identify the attribute, each attribute should be identified...
Is it possible to enable or disable the parameter EnableAutoBackFilling for different group of Analysis in different database.
The idea is to not have same parameter EnableAutoBackFilling for all Analysis of all databases on the same ...
AF function PrevEvent() should return timestamp of previous event even if data is "No Data"
Normally AF function PrevEvent() returns the timestamp of the previous event for a specified timestamp.
But if the previous event is system digital state "No Data" it does not return the timestamp but again system digital state "No Data". That is...
If you have a PI Tag that fluctuates within very excessive ranges, then it becomes quite difficult to observe its trending patterns in a chart because of its volatility.
A feature to smooth the volatile values (i.e. exclude those outside of a use...
Create a Flag for AFGetTrace to Show Calculation Steps for Analysis Data References
Background:
Currently, the only why to troubleshoot the analysis service is to set the trace levels through the various config files. This only works when the analytic engine is being used. In other words, this only works if the analy...
Currently it is only possible to specify one timestamp override per analysis. I would like a way to set a conditional based timestamp override that way the output timestamp could vary based on the result of an analysis.