Skip Numbers in Digital State / Digital Set

There are other similar ideas out there on this site but I would like to see the ability to skip numbers in the Digital States Enumeration. We have areas of the plant that have states which don't map well to a 1,2,3.... set of states. Some are bit...
Guest over 2 years ago in System Management 1 No status

several Instances for PI Relay

Having the PI Relay for OPC UA Connector running on a different machine than the actual connector is a good Idea, as we are now able to provide Windows credentials for AF Access without Credential manager. On our Site we are running several small...
Guest over 2 years ago in System Management 0 No status

PI SMT - Archive Editor Improvements

Why is the second server of all selected servers the default selected server for the archive editor? (C# index 1 instead of 0?) If I leave the Tagname empty and press the search button the tag search dialog opens fine. But if I enter some text at...
HolgerJoistOmv over 2 years ago in System Management 0 No status

Increase Box Length for Tagname Field in Archive Editor

The Tagname field visible length should be increased within Archive Editor in System Management Tools. The full tag name is limited and cannot tell what is listed because the name is cut off. (See screenshot and steps listed below.) Steps to repr...
Guest over 2 years ago in System Management 0 No status

Improve Digital State Set Management

We have hundreds of digital state sets, many of them the same with the exception of their name (e.g., Manual_Auto, ManualAuto, Manual-Auto, Manuel-Auto, ManuelAutomatique; all with states 0: Manual and 1: Auto). In order to clean up these states, ...
Kelsey Bobeck over 1 year ago in System Management 0 No status

Archive Editor: Preserve the selection of multiple rows when right-clicking on a cell within the selection

Currently, if you select multiple rows in the Archive Editor and then right-click on a cell that is not the ► cell or the Value cell beside it, your selection will collapse to the row whose cell you right-clicked. That is, no matter how many rows...
Guest over 2 years ago in System Management 1 No status

Revise tuning parameter descriptions

As a general suggestion, please look through all the tuning parameter descriptions and fix any mistakes or inconsistencies between descriptions. This includes the ones that the user cannot see by default. All: Almost every tuning parameter descri...
Guest over 2 years ago in System Management 0 Declined