Allow BadVal to check multiple inputs or IFERROR

Right now BadVal can only check one variable or Expression.  So if I am evaluating an expression with say 10 inputs, and I want the expression to output NoOutput() if any one of the 10 inputs are BadVal, then I have 2 options right now. ...
Guest almost 3 years ago in Analytics & Calculations 5 No status

Event Frames that can expire/auto-delete/archive

When generating Event Frames it would be useful to automatically remove the Event Frame, either when no longer active or in combination with no longer active and acknowledged, or other conditions. An example use case would be for PI Notifications...
Guest almost 3 years ago in Event Frames (EF) 0 No status

PI Notifications (2.X) Acknowledgement Page

Currently, the only way to acknowledge a notification in PI Notifications (2.X) is to acknowledge the event frame in PI Vision. Not all customer's have PI Vision. Therefore, the Acknoledgment Site from PI Notifications (1.X) should be upgraded t...
Guest almost 3 years ago in Notifications 2 Declined

Improvement of AF Identities/Mappings - Make it similar to PI Data Archive

When adding a Mapping to an Identity in the AF Server this will always generate a new mapping linked to a user/group account. If this user/group account it's already mapped to an identity then, by default, it will add 1 to the mapping name. If...
Guest almost 3 years ago in Asset Framework (AF) 1 Declined

Use Excel tables to contain PI Builder data

PI Builder should use tables (the kind of table found in the Insert tab on the Ribbon) whenever headers are set up and whenever data is imported from the PI Data Archive or the PI Asset Framework. Benefits of PI Builder using tables: • filters ar...
Guest almost 3 years ago in PI Builder 1 No status

Totalizer that resets to 0 with Asset based Analytics

I need to calculate a running sum (totalizer) of a PI Point and reset it to 0 at the beginning of each month. I would like to do this with Asset based Analytics. There are workarounds to do this, but none are great. For example, one workaround inv...
Guest almost 3 years ago in Analytics & Calculations 2 No status

Use %Duration% with Formula Data Reference as Best Practice for EF Duration Attribute (AF 2017 R2+)

This is a followup to discussions with Roger Palmen and Rick Davin about their excellent writeups on the topic of EF Duration attributes; see Event Frame duration - easy way in AF2.6 or higher & Duration attribute on an Event Frame - Part 1 , ...
Guest almost 3 years ago in Asset Framework (AF) 1 Declined

PI SMT's Current Values plug-in should have an option to not display comma separators for large numbers.

PI System Management Tools currently displays comma separators for large numbers. For example: 1,000,000. As a PI admin/user, it would be beneficial if there was an option to remove these commas.
Guest 7 months ago in Data Archive 0 No status

As an administrator, I would like to be able to backfill data that crosses over a versioning event

Use case: 1. An element has an attribute that looks up information on equipment configuration (ex: a pump rate) 2.  Due to an equipment change, the lookup table and the element were increased in version 3. A backfill needed to be performed o...
Guest almost 3 years ago in Analytics & Calculations 1 No status

Skip Numbers in Digital State / Digital Set

There are other similar ideas out there on this site but I would like to see the ability to skip numbers in the Digital States Enumeration. We have areas of the plant that have states which don't map well to a 1,2,3.... set of states. Some are bit...