As an avid user/admin of AF, in PSE I would like an option to display large attribute values with commas
Currently, in PSE there is no way to display attribute values greater than or equal to 1000 with commas for the thousands separators. Ex: 1,234,456 instead of 123456. This option exists in other PI Clients (i.e. PI Vision) and should be available ...
Ability to use substitution parameters in attribute template names
Would like ability to use substitution parameters in attribute template names. Using PI-SNMP for Linux file partition data. We need to know the storage index# in AF since they vary server to server. Want to provide users doing searches the actua...
Formula data references do not support string value type attributes (e.g. if stringattribute="Yes" then "X" else "Y"). One workaround is to create an analysis on the element template with the same logic mapped to an attribute on the element templa...
Currently, AF search results can only be sorted by a single field. It would be useful to have the capability to specify 2 (or more) SortField values so that the order of results can be guaranteed in the result of a tie.
For example, being able to...
Compare exported AF templates to other environments
A feature to review the changes that will be made when importing AF templates that have been exported from a lower environment.
Example.
Make changes to element/attribute/archive templates in dev. Export library to XML. Compare export to QA tem...
As a AF Administrator, I would like to be able to define a list of synonym names for attributes associated with an element template SO THAT different sites leveraging the template can have their attributes shown based on their "local" terminology....
Allow the use of filter expressions, similarly PI DataLink Compressed Data, so that you can visualize or perform calculations on filtered data (e.g., excluding bad values, certain digital states, etc.).
Ability to change the timezone used in PI System Explorer with a feature similar to what is found in PI DataLink or PI SMT 2017.
As an end user, I would like to be able to change the timezone referenced in PI System Exporer from client timezone to server timezone. Something similar to the "PI Data Archive Time Zone" setting found in PI DataLink would be helpful.
AF Audit Trail for deleted items should retain friendly database name
Would like AF audit trail to retain friendly database name for deleted items. Currently it removes the friendly database name making it very difficult to track changes made to a specific database once an item is deleted.
I would like the ability to embed a substitution parameter within another substitution parameter.
For example, in the following Configuration String:
\\%Server%\%@||TagName%
I would like to replace with a substitution parameter