Showing 849

Remove installation kits' dependency on write permission to root C:\.

Some organizations do not provide admin accounts with write permission to the root C:\ directory. The install kits of most PI products copy the setup.ini to C:\pisetup.ini, and then write the logs to C:\ before moving them to %pipc%\dat, both of w...
Guest almost 3 years ago in Installation 4 No status

PI Auditviewer Usability Enhancements

From a pharma/biotech user perspective, I am finding that the PI Auditviewer application is difficult to use and conduct an investigation with over an extended time period.  I believe the application needs an overhaul to allow for, at minimum...
Guest almost 3 years ago in General 1 No status

Enable tracing for one individual Analysis

On a highly loaded system with thousands of analysis i have one analysis that is misbehaving, missing executions but no skipped count, etc. Currently tracing enables tracing for ALL analysis creating an ocean of logging to plough through for that ...
Roger Palmen almost 3 years ago in Analytics & Calculations 5 No status

Allow EventFrame("Duration") to be used as an EndTrigger

I want to stop my Event Frame after an amount of time that is stored in an AF Attribute. For my use case, the amount of time from the beginning of an Event Fame is an end triggering condition. One way to do this, would be to allow the EventFrame("...
Guest almost 3 years ago in Analytics & Calculations 4 No status

Acknowledge of Event Frames requires Reason Code / Comment / Electronic Signature

It should be possible to configure event frames to be acknowledgeable only if a comment/reason code is entered before. we have this requirement sometimes in life science industry, but i can imagine it might be also usefull in other industries (e.g...
Guest almost 3 years ago in Event Frames (EF) 2 No status

Native configuration promotion from test to production servers

As a PI Administrator with a test PI Server, I need to be able to easily promote configurations from our test environment to our production environment. Currently this is extremely difficult and a very manual process.
Guest almost 3 years ago in System Management 2 No status

Auditviewer App Suggestion

I want the ability to determine what PI System Configuration Changes (AF & PI Data Archive) are legitimate and approved, with the criteria of being able to focus on changes that occurred during a user defined time range. I want to minimize the...
Guest almost 3 years ago in System Management 15 No status

Add additional Analysis Search Criteria options to PSE Management

It would be helpful if you could search by Element Category or Element Description when searching for Analyses in PSE. My setup is 5 templates (CHW, Water, HW, Electric, Steam), each of which have accounts that can come from 5 different sources (s...
Kelsey Bobeck almost 3 years ago in Asset Framework (AF) 2 No status

Ability to embed substitution parameters

I would like the ability to embed a substitution parameter within another substitution parameter. For example, in the following Configuration String: \\%Server%\%@||TagName% I would like to replace with a substitution parameter
Guest almost 3 years ago in Asset Framework (AF) 2 No status

Pi System Explorer: Display Check-In History Per User

I would like to be able to see a log of when users checked in changes to the system in PSE. I recently checked in changes to our PSE system and around the same time, the CPU pegged of SQL server and the analyses slowed way down and other functiona...