Skip to Main Content
AVEVA Product Feedback


ADD A NEW IDEA

Search results

Showing 19

Enhance functionality of NumOfChanges

By now the NumOfChanges Function in AF Analytics does not take into account the value at the start of the timerange. NumOfChanges only counts the amount of changed values of the recorded values in the given timeframe. If I query the NumOfChanges ...
Guest over 2 years ago in Analytics & Calculations 4 No status

PI Point User Settings in AF Client

The Suggested PI Point Name configuration item in the AF Client should be able to be set on a AF Server basis instead of a User basis, at least as the initial default. There are default parameters we need to enforce from an enterprise/site level b...
Matt Voll over 2 years ago in Analytics & Calculations 7 No status

Totalizer that resets to 0 with Asset based Analytics

I need to calculate a running sum (totalizer) of a PI Point and reset it to 0 at the beginning of each month. I would like to do this with Asset based Analytics. There are workarounds to do this, but none are great. For example, one workaround inv...
Guest over 2 years ago in Analytics & Calculations 2 No status

Allow nameless arrays in Notifications JSON

Currently, when configuring JSON as the body of a Notification, an array of items has to have a property name--there isn't a way to construct an array of JSON objects where the array isn't prefixed with "name": or some other property name. There a...
Guest over 2 years ago in Notifications 0 No status

Maximum security should be the default for the PI Data Archive and PI System Management Tools

Maximum security by default would help encourage security best practices by: Making the best decision for customers that do not know or care about security "Rewarding" security-conscious customers with not having to expend effort to maximize secur...
Guest over 2 years ago in Security 0 No status

Allow bools to be unpacked from Integers

AF should allow you to have a PI Point Data Reference as individual bits within an INT. Ex. PIPOINTA is an int16 or int32. PIPOINTA.0 and PIPOINTA.1...etc.. should be able to be mapped to a bool attribute. (where .0 is the 0th spot in the integer ...
Guest over 2 years ago in Asset Framework (AF) 1 No status

Access Attribute Template Array member value using index in name substitution

Would like ability to use the value of an attribute array values when doing name substitution like %@attribute1[0]%
Guest over 2 years ago in Asset Framework (AF) 0 No status

Polybase Support with PI SQL Client

Creating a Polybase External Table with a PI SQL Client connection via ODBC causes query errors showing only it only supports column-wise binding. Polybase attempts to utilize row-wise binding which is not supported. Developers and customers have ...
Guest over 2 years ago in General 0 No status

Allow scheduled analyses to ignore circularity

It should be possible to force an apparent circularity to be ignored if analyses are scheduled and not triggered. A thermal efficiency application I have coded as AF Analyses has the following two analyses A and B, such that each is expressed in ...
Guest over 2 years ago in Analytics & Calculations 1 No status

Summary of the children event frame duration based on the trigger or severity

As a consumer of event frame data, I would like to be able to get a summary of the children event frame duration based on the trigger or severity over the duration of parent event frame when a parent event frame closes. The output should be stored...
Guest over 2 years ago in Analytics & Calculations 1 No status