Allow PI Server components to be removed at installation time

Currently, when you run the PI Server install kit to perform an upgrade, existing PI Server components cannot be unselected, and so they are upgraded. This gives the impression that they cannot be uninstalled, but they can actually be uninstalled ...
Guest about 3 years ago in Installation 0 Declined

Log SQL server name when throwing network-related or instance-specific errors

When the AF Server throws a network-related or instance-specific SQL error it only says that it failed to establish a connection to "SQL Server". It further says to check if the instance name is correct. However, it never says to what SQL server...
Guest about 3 years ago in Asset Framework (AF) 0 Declined

Add pH to the UOM database

pH is a common enough unit that it should be in the UOM database by default. It is also tricky for customers to add pH themselves and get the dimensions correct, so it is best that OSIsoft does this for us.
Guest about 3 years ago in Asset Framework (AF) 3 Declined

Saving the "Analysis Service Statistics" should be saved in XML instead of TXT since this is the actual format of the file

It is possible to change the format after it is saved, but it should natively  be saved as an XML.
Guest about 3 years ago in Asset Framework (AF) 1 Declined

Analysis Searches - Allow Searching by 'Backilling'

In PI System Explorer under the Management tab, add a new search category in Analysis Searches to allow searching by Backfilling.  The Backfilling status column is always shown in the results window, but there is no way to search by this column.
Guest about 3 years ago in Asset Framework (AF) 1 Declined

Add a UOM class for bit rate

More generally, the UOM class should capture information per time. This is useful for labelling data transfer speeds and signal quality.
Guest about 3 years ago in Asset Framework (AF) 0 Declined

Use superscript characters in UOM abbreviations

Currently, exponents in UOM abbreviations are not superscripted (e.g. cm2, ft3). Please use the proper superscript characters for these (e.g. cm², ft³).
Guest about 3 years ago in Asset Framework (AF) 0 Declined

Be able to add child attributes to attributes that use limit traits

Currently, if an attribute has a limit trait assigned to it, it cannot have child attributes. This seems somewhat arbitrary. Child attributes of attributes with limit traits would be useful for high/low warnings/alarms.
Guest about 3 years ago in Asset Framework (AF) 1 Declined

Use "whole" as the canonical UOM of the Ratio UOM class

The Ratio UOM class represents part-to-whole ratios (i.e. the units are relative to the whole). Also, ratios are the result of a division. The division produces the number of wholes that the part represents. Any other ratio unit (e.g. %) requires ...
Guest about 3 years ago in Asset Framework (AF) 1 Declined

Have an easy way to expand the entire attribute hierarchy

Elements usually do not have tens or hundreds of attributes. A lot of the time, it would be nice to be able to expand the attribute hierarchy all at once rather than expand each parent attribute separately.