Copy paste issue for child attributes

On PI System explorer when you copy an attribute with child attributes, only the first child attribute get's copied as well and the rest is missing. This was working with PI System Explorer 2016 R2 SP1 whereas it does not with Version 2018 SP3 pat...
Guest 11 months ago in Asset Framework (AF) 0 No status

Composite element templates

As an user I want to be able to create a template hierarchy (parent-child) all at once, so that I can easily create a hierarchy representing related assets. For example, create a motor, gearbox, compressor train with a single template that actuall...
Guest about 3 years ago in Asset Framework (AF) 4 No status

AF Recalculation of most recent execution

Enable the ability of the Analyses to recalculate the most recent exeuction. When manually entered data is utilized in an AF Analyses, under a variety of analysis configurations, the most likely analysis execution needing to be recalculated is the...
Matt Voll 2 months ago in Asset Framework (AF) 0 No status

Add support to schedule AF table lookups at precise times

I need more precise control over the timing of table lookups in AF, specifically the ability to schedule them at exact times (such as midnight) rather than relying on the current minimum refresh interval mechanism. AF table connections currently s...
Janelle Minich 4 months ago in Asset Framework (AF) 1 No status

Row/variable information to AF Analysis errors

When we built complex analysis and evaluate in PI System explorer we get general error messages without any information where the error occurs. This makes troubleshooting painful. Adding row/variable information would already help a lot!
Guest 11 months ago in Asset Framework (AF) 0 No status

if then else in Analysis still checking/executing both parts

If then else clauses are often used for input filtering for our analysis in AF. We often face the issue that analysis cause errors although the part which should not be executed according to the condition is causing errors.Example: "if BadVal('att...
Guest 11 months ago in Asset Framework (AF) 1 No status

PI AF Template Versioning

Allow for PI AF templates to be version controlled. Include the ability to revert to previous template version, or continue to use old versions for specific elements. This will reduce the risk of deployment and improve change/release management pr...
Guest about 3 years ago in Asset Framework (AF) 3 No status

Option to paste column names to AF table definition

Option to Paste column names in table definition. In the moment everything has to be put manually. Also sorting is painful. If we could just copy an array/list from Excel and paste here it would make the handling a lot easier. (Copying the table d...
Guest 11 months ago in Asset Framework (AF) 1 No status

Change default setting for new analysis templates enabling from True to False

When an analysis template is added or new analysis are created with PI Builder the default option is to "enable analyses when created from template" = True. This should be changed to false with an opt-in for automatic enabling. Users easily forget...
Guest 11 months ago in Asset Framework (AF) 1 No status

Executing query or stored procedure directly from AF analysis

Currently you can add a query or stored procedure to the library in AF. From there you can retrieve data to be used in an attribute via table lookup. What I am looking for however, is to be able to directly execute a stored procedure from an analy...