Skip to Main Content
AVEVA Product Feedback


ADD A NEW IDEA

Asset Framework (AF)

Subsecond timestamp precision visibility in PI System Explorer

Currently with PI System Explorerwill display up to millisecond precision (3 decimal places) if the timestamp contains subseconds. This is the current default setting cannot be changed. It would be useful to have a feature in PSE where users can d...
Guest 5 months ago in Asset Framework (AF) 0 No status

Attribute Synonyms

As a AF Administrator, I would like to be able to define a list of synonym names for attributes associated with an element template SO THAT different sites leveraging the template can have their attributes shown based on their "local" terminology....
Guest about 4 years ago in Asset Framework (AF) 6 Declined

Export/Import Contact Groups and/or Delivery Endpoints to XML from PI System Explorer

Please allow one to export, and import, to XML from PI System Explorer Contact Groups and/or Contact Delivery Endpoints.  Doing this with AFExport.exe and AFImport.exe on the AF Server is cumbersome and restrictive.
Guest about 4 years ago in Asset Framework (AF) 2 No status

Option to paste column names to AF table definition

Option to Paste column names in table definition. In the moment everything has to be put manually. Also sorting is painful. If we could just copy an array/list from Excel and paste here it would make the handling a lot easier. (Copying the table d...
Philipp Even about 2 years ago in Asset Framework (AF) 1 No status

Remove Templates for Elements in PI System Explorer

Currently, when you remove a template from an Element in PI System Explorer, you'll remove all existing attributes from the Element. There should be a functionality in PI System Explorer to remove the template without making changes to the attrib...
Guest about 4 years ago in Asset Framework (AF) 1 No status

Improve PI Data Security

The assignment of a PI tag on which the currently logged in user has no authorization as PI point reference to an AF attribute must not (as currently) be possible. It is possible to bypass the PI Archive authorization mechanism (point and data sec...
Guest about 4 years ago in Asset Framework (AF) 5 No status

Include logs for when an AF database is deleted in the AF event viewer logs

Currently, to confirm when an AF database has been deleted + by which user, AF audit trail needs to be enabled. Audit trails tend to take up a lot of space and many users decide not to enable them. It would be beneficial to include logs each time ...
Guest almost 4 years ago in Asset Framework (AF) 0 No status

Improving Readability of AF Identity Change Logs in Audit Viewer

We are using PI AF Audit to monitor changes in AF security. After changing the AF Identity of a certain element, we checked the corresponding Identity change in Audit Viewer. However, in Audit Viewer, the Identity name, New Value, and Old Value ar...
Guest 3 months ago in Asset Framework (AF) 0 No status

Provide option to re-use or not re-use OIDC access tokens when connecting to multiple AF systems using PI System Explorer

At the moment, PI System Explorer defaults to re-using OIDC access tokens when connecting between AF systems. For customer systems where there are multiple independent AIM servers for different AF systems (potentially because of different countrie...
Guest 9 months ago in Asset Framework (AF) 0 No status

Allow to hide Elements

Now we can hide individual attributes. I would like to hide elements too. We can use this to hide configuration elements, prevent setting many (all) attributes to hidden, hide unused elements, etc. Thinking this through, this implies that all chil...
Roger Palmen about 4 years ago in Asset Framework (AF) 2 Declined