Allow EventFrame("Duration") to be used as an EndTrigger

I want to stop my Event Frame after an amount of time that is stored in an AF Attribute. For my use case, the amount of time from the beginning of an Event Fame is an end triggering condition. One way to do this, would be to allow the EventFrame("...
Guest about 3 years ago in Analytics & Calculations 5 No status

multiple instances of analysis service

As a PI administrator I would like to be able to create multiple instances of "PI Analysis Service" windows service for these reasons: - avoid new potentially problematic analysis from affecting the ones that are operational and working correctly ...
Guest about 3 years ago in Analytics & Calculations 6 No status

Aggregate event frames to a time series

As an user, I want to be able to treat event frame like time series data, such as number of active event frames, sum of an attribute, so that I can continuously monitor the evolution of event frames over time.
Guest about 3 years ago in Event Frames (EF) 4 No status

Stop EF after given time

Als a PI admin I want to have the option to stop/end a EF after a given time. This helps to trigger and track onetime events as for example taking a reactor sample.
Guest about 3 years ago in Event Frames (EF) 3 No status

Ability to embed substitution parameters

I would like the ability to embed a substitution parameter within another substitution parameter. For example, in the following Configuration String: \\%Server%\%@||TagName% I would like to replace with a substitution parameter
Guest about 3 years ago in Asset Framework (AF) 2 No status

Increase the sub seconds to be more that 3 decimal places in PSE UI

We faced an issue with thinking the formula DR time series data in PI System Explorer was duplicating results but that was because the sub seconds were not showing and there were difference in the sub seconds for the two results which we thought w...
Guest about 2 years ago in Asset Framework (AF) 1 No status

Remove installation kits' dependency on write permission to root C:\.

Some organizations do not provide admin accounts with write permission to the root C:\ directory. The install kits of most PI products copy the setup.ini to C:\pisetup.ini, and then write the logs to C:\ before moving them to %pipc%\dat, both of w...
Guest about 3 years ago in Installation 4 No status

PI Auditviewer Usability Enhancements

From a pharma/biotech user perspective, I am finding that the PI Auditviewer application is difficult to use and conduct an investigation with over an extended time period.  I believe the application needs an overhaul to allow for, at minimum...
Guest about 3 years ago in General 1 No status

Enable tracing for one individual Analysis

On a highly loaded system with thousands of analysis i have one analysis that is misbehaving, missing executions but no skipped count, etc. Currently tracing enables tracing for ALL analysis creating an ocean of logging to plough through for that ...
Roger Palmen about 3 years ago in Analytics & Calculations 5 No status

Acknowledge of Event Frames requires Reason Code / Comment / Electronic Signature

It should be possible to configure event frames to be acknowledgeable only if a comment/reason code is entered before. we have this requirement sometimes in life science industry, but i can imagine it might be also usefull in other industries (e.g...
Guest about 3 years ago in Event Frames (EF) 2 No status