A way to specify within analyses whether input values should be retrieved from the Data Archive or the PIAF Cache
A way to specify within the analyses if input values should be retrieved from the Data Archive or the PIAF Cache. Thereby preventing different results during real-time calculation and for instance backfills and decreasing the execution time of ana...
Increase the allowed password length for AF Linked Table "Supply Password" connections
Currently the maximum password length for AF Linked Table connections using the "Supply Password" option is 15 characters. This length limitation should be increased to at least 25 characters.
1. AF Transformer should be able to sync changes made in the source AF Database: if an element is added, deleted or edited. For the deletions there should be a way to select the behavior: delete an object from the target database, place it u...
One of the items i need to build frequently, yet no support in analytics yet.
I want to habe an AF Analysis function that returns the number of seconds a value of an attribute has changed. E.g. to calculate how long a pump is running, how long a b...
It can be difficult to locate an analysis group in the current (2.9.5) UI for the Analysis Statistics in a large system. Currently the groups are organized in decreasing order of lag which is great to troubleshoot latency issues. However, if one w...
Editing or adding of Annotation/Comment to Event Frame
Currently, PI Builder does not support editing or adding of annotation/comment to Event Frame. The suggestion will easily allow users to backfill or edit annotation/comment in bulk.
Option to not capture value for event frames generation
As an engineer I need the option to not capture values for event frames generation so that if I have out-of-order events, I don't have to recapture the values.
Note: This was previously Enhancement 114349.
Add a function to calculate the week number of the year
In order to calculate the current shift operating at a plant, I need to calculate where in the 28-day cycle the current week is. Knowing which week of the year it is allows me to do that. Note that current PI weekday functions always count Sunday ...
Allow a default value to be specified for rollup analysis. This value would be used when the rollup cannot find any matching attributes, thereby eliminating a lot of rollup analysis errors and Calc Failed values from being written.
Reason Code value to AF element attribute or PI Tag
As a PI system user, I need the ability to use reason codes to develop reports and dashboards. The current functionality of PI Vision symbols and analytics do not really enable the use of the current data type of EF attribute.
The ability to map ...