As a user of Asset Analytics I would like to have more flexibility in including elements in my rollup calculation so that I would not need to build large hierarchies just for the purpose of rollup analyses.
Add the triggers to SQC rules to reset or hold the SQC rule. When monitoring a periodic or batch based process, a user needs to be able to hold the SQC rule or put that rule in a hold state until the process resumes. Without this feature, virtuall...
The Suggested PI Point Name configuration item in the AF Client should be able to be set on a AF Server basis instead of a User basis, at least as the initial default. There are default parameters we need to enforce from an enterprise/site level b...
We've several PI servers and AF servers where same products are running, so we need the ability to search Event Frames across our AF databases to compare production performance. This search ability should be available in all clients; PI Vision, Da...
Allow exclusion of message types when searching PI Message logs
As a PI System administator of a busy PI Data Archive, I find that my message logs are unwieldy. I can miss important messages in the flood of connection messages and other repetitive messages. I would like to be able to search my message logs whi...
Export/Import Contact Groups and/or Delivery Endpoints to XML from PI System Explorer
Please allow one to export, and import, to XML from PI System Explorer Contact Groups and/or Contact Delivery Endpoints. Doing this with AFExport.exe and AFImport.exe on the AF Server is cumbersome and restrictive.
PI-DataLink allows for filtering of aggregate calculations, for example to get the average inlet temperature of a compressor when the turbine speed is > 1000 RPM.
This is not possible with AF. The KB01120 article does not work and is very mess...
Make it easier to get a list of buffered or unbuffered points on the PI Data Archive
For PI System Administrators, it would be nice to be able to easily get a list of all buffered or unbuffered points on the PI Data Archive.
Currently, a list of buffered points is possible to retrieve using 'piartool -bfs -ptlist', but a comprehe...
Guest
over 2 years ago
in Data Archive
0
No status
Delay Real-Time Calculations until backfill is finished.
For recursive Analyses such as below :
PrevVal(tagA,'*') + 'TagB' → output : tagA
When the PI Analysis Service is down (or the node needs to be restarted), the current calculation needs to be halted until the Backfilling reaches up to the start u...
Ability to override analysis in a derived template
When i create a derived Element Template, i would like to be able to override an inherited analysis. Now i am severly limited in the re-use of templates due to this limitation. I cannot extend nor exclude functionality in a derived template if thi...