Skip to Main Content
AVEVA Product Feedback


ADD A NEW IDEA

All ideas

Showing 1357 of 1357

Improve PI Data Security

The assignment of a PI tag on which the currently logged in user has no authorization as PI point reference to an AF attribute must not (as currently) be possible. It is possible to bypass the PI Archive authorization mechanism (point and data sec...
Guest over 3 years ago in Asset Framework (AF) 5 No status

Include logs for when an AF database is deleted in the AF event viewer logs

Currently, to confirm when an AF database has been deleted + by which user, AF audit trail needs to be enabled. Audit trails tend to take up a lot of space and many users decide not to enable them. It would be beneficial to include logs each time ...
Guest about 3 years ago in Asset Framework (AF) 0 No status

Feature to enable notification rules automatically

When deactivating an alarm, the notification rule is disabled. There should be a way to set a notification rule to be enabled in a certain number of days. For example, if I disable the notification rule, I want to set it to be reenabled automatica...
Guest 5 months ago in Notifications 1 No status

Add support to schedule AF table lookups at precise times

I need more precise control over the timing of table lookups in AF, specifically the ability to schedule them at exact times (such as midnight) rather than relying on the current minimum refresh interval mechanism. AF table connections currently s...
Janelle Minich 10 months ago in Asset Framework (AF) 1 No status

A way to specify within analyses whether input values should be retrieved from the Data Archive or the PIAF Cache

A way to specify within the analyses if input values should be retrieved from the Data Archive or the PIAF Cache. Thereby preventing different results during real-time calculation and for instance backfills and decreasing the execution time of ana...
David Scott almost 2 years ago in Analytics & Calculations 1 No status

Utility to completely uninstall all OSIsoft PI products from a machine

It would be helping to have a utility do a complete uninstall of all the PI products from a machine including registry keys and hidden files.
Guest over 3 years ago in Installation 2 Declined

Add Access Right that Allow Users to Create Tags But Not Delete Tags

As a user of the PI Data Archive, I would like the ability to give users access to create tags but not to be able to delete tags. This way they will not be able to accidentally delete tags but they still have the ability to create tags.
Guest over 3 years ago in Data Archive 5 No status

Put an Asset into Offline Mode which stops related analyses and notifications

Have a way to manually (or automatically via another calculation/analytic) put the status of an asset/equipment into an offline/maintenance mode that has the effect of turning any analyses and notifications for that asset off.
Guest over 3 years ago in Analytics & Calculations 0 No status

Option to use Good Data only in Analyses.

Analyses can suffer from bad calculations due to bad events for a tag, such as system digital state events returned for a numerical tag. Although BadVal() can be implemented to avoid using bad events in these analyses, they add another layer of ...
Guest over 3 years ago in Analytics & Calculations 2 No status

Trigger Rollup Analysis Upon Adding Child Elements

It would be useful to trigger event-triggered rollup analyses upon adding new children. Currently rollup analyses are only triggered when rollup attributes are updated (and not triggered when rollup attributes are added). This would be particularl...
Guest over 3 years ago in Analytics & Calculations 1 No status