Include logs for when an AF database is deleted in the AF event viewer logs
Currently, to confirm when an AF database has been deleted + by which user, AF audit trail needs to be enabled. Audit trails tend to take up a lot of space and many users decide not to enable them. It would be beneficial to include logs each time ...
Provide a way to backfill/recalculate analyses from Analysis Template tab in PSE
It is difficult to find all the analyses from template to backfill/recalculate after making changes in Analysis Template. Currently one has to navigate to the Management plug-in, do some sort of search/filter, then queue the analyses. ...
When a failover occur or at service startup, ALL analysis configured for backfilling executes based on the last configured backfill/recalculate timerange.
There is actually no feature to manually remove a configured backfill on a specific analysis.
Include subseconds in output timestamp from variable
Currently we have an analysis with the output timestamp set to be a variable within the analysis. If I map that variable to an output, it includes the subseconds, but the output time for the analysis is truncated to the second. The output time for...
When editing PI Points, PI Builder does not return any error if one of the headers is wrong or misspelled. Simply, nothing is edited for that header and you only find out at a later time when looking at the PI point. It would be useful if PI...
Guest
almost 3 years ago
in PI Builder
2
No status
PI System Explorer shows the creation date and last changed date of AF objects by default
As a PI System Explorer user I want to be able to see when was the creation date and last changed date of an AF object without enabling the Audit Trail, similar to the PI SMT feature which is easily accessible and works by default.
Allow object specific Audit Trails to be accessed by object level Administrators
Currently to view the Audit Trails of any object on an AF Server, Server level Administrator privileges are needed.
There should be the ability for a user that does not have server level administrator to view the Audit Trails of a specific object...
Incremental backups are not possible because of frequent backfilling
Occasional back filling of data would cause 5 TB of archives to be backed up with incremental backups. This is frustrating because only a few KB of data is changed in each archive. Can OSIsoft provide a way to backup only the data that has changed...
Guest
almost 3 years ago
in Data Archive
3
No status
Allow arguments/parameters to be passed to variable definitions, effectively creating user-defined functions.
For example, suppose that I want to define the function TagSum, which adds the values at all events in a time range. Then:
TagSum(tag, s...