Add array sorting function to AF Analytics.

This would also enable calculation of percentiles. Percentile calculation would also be possible if the user could use nested substitution parameters in array functions. For example: RecVals := RecordedValues('Attribute1', start, end) CountLowe...
Guest about 3 years ago in Asset Framework (AF) 0 No status

TagTot should make use of input UOM when no output UOM is defined

TagTot will automatically account for UOM that have the time dimension as something other than per day only when the input has an assigned UOM and the function has an output UOM defined. It would be friendlier if the output UOM was defaulted based...
Guest 8 months ago in Analytics & Calculations 0 No status

Archive corruption detection

For the moment some Archive corruption are not detected automatically by PI DA. For example error -15000 due to archive corruption. Please enhanced the archive corruption detection because we have more and more long history and it can become diffi...
Guest over 2 years ago in Data Archive 0 No status

Prevent Analysis calc failure for attribute not found

If the same analysis is trying to be used for multiple templates, there will be times when some attributes are not available from a template - this will cause the analysis to fail. Even when the difference in attributes is known and attempted to b...
Guest over 1 year ago in Asset Framework (AF) 0 No status

Allow adding naming conventions

Administrating large systems require providing naming standards (for example when implementing international standards like ISA95) for various system elements: PI Point, AF DBs, Elements, Templates and so on. AVEVA software could support naming co...
Guest over 1 year ago in System Management 0 No status

PI Notifications automated emails need to display all receivers of the automated emails from the PI Notifications application, not just the singular user (me in this case).

PI Notifications automated emails need to display all receivers of the automated emails in the list of emails that the automated email was sent to. It is very important for the user (or receiver of the automated PI Notification email) to understan...
Guest almost 2 years ago in Notifications 1 No status

Update a Subset of Event Frames' Security Without Changing "Modified Date"

Currently, there is not a way to update a subset of Event Frames' security in bulk, without changing the Event Frame's "Modified Date." For example, to add a new AF Identity with "read" permissions to a subset of Event Frames. Some customers use d...
Guest over 1 year ago in Event Frames (EF) 0 No status

Ability for admins to restrict PI Data query to 2 years at a time.

I would like to restrict PI Vision users from pulling data for more than 2 years at a stretch. This setting should also restrict the PI Data link as well. This will make the software more robust to query timeout. Just let users know they need to a...
Ronald Main about 2 years ago in Data Archive 0 No status

Fix for KI: EventFrame Extended property not removed after EF is closed

The first EFs created by the PI Analysis Service after a restart can have the Extended Property StatusInAnalysisService stuck in Reconciling even after the event frame has been closed. There is a workaround to fix the issue when it occurs (see Eve...
Guest over 1 year ago in Analytics & Calculations 1 No status

Add filter clause in PI Builder Attribute Search dialog for AttributeDataReference

In the Attribute search dialog in PI Builder, add in the list of where clauses the ability to filter by AttributeDataReference.