Convert should allow to override UOM

The introduction of the property "Delta UOM", made clear that when an incorrect UOM is set for an analysis result, there is no way (except casting to text and back to number) to change the UOM to a UOM of a different class. We need the convert fun...
Roger Palmen over 3 years ago in Asset Framework (AF) 2 No status

Add an option to mark the PI Point Data Reference to not be updated when a Create or Update data Reference is issued

Currently when a PI Point Data Reference receives a call telling to Create or Update the Data Reference, it will resolve the String builder and then lock that Data Reference so that if someone changes the template, that change will not be replicat...
Guest over 3 years ago in Asset Framework (AF) 1 Declined

Allow programmatic access to AF audit trail for report generation

As a PI admin I would like to be able to generate reports based on the AF audit trail.  Currently the audit trail can be accessed manually using the audit trail utility tool and manually output a file, though I would like to be able to query ...
Guest over 3 years ago in Asset Framework (AF) 2 No status

PI System Explorer Define Table tab should add new rows below the working row, rather than above

When defning a table in PSE the new row button adds the new row above the row I'm currently working on, it should go below the row I'm working on, since I logically want to add the next column in my table.
Guest over 3 years ago in Asset Framework (AF) 1 Declined

Don't run previous query when opening trend in PI System Explorer

When right-clicking and opening a trend or time series data, don't run the previous query. It can take too long. i.e. I loaded one year of data from a daily total tag (365 values). The next attribute I trend is a one-second tag (31 million values ...
Guest over 3 years ago in Asset Framework (AF) 0 Declined

Make AFDiag timeout based on AFService.exe.config settings

Make AFDiag timeout parameter based on AFService.exe.config settings instead of being hard coded.
Guest over 3 years ago in Asset Framework (AF) 2 No status

Customized PI System Explorer view

Currently PI System Explorer views lots of stuff that is not used by most users (ports, models etc.) also, there are some things that may depend on decisions of particular client - for example, I don't want my users to use Formulas. I suggest to p...
Guest over 3 years ago in Asset Framework (AF) 2 No status

Include AFDiag /AddIdentity functionality to PSE

Adding an identity to an established large system can cause a flood of change records, leading to performance issues. The AFDiag /AddIdentity feature will bypass this issue, but it would be more convenient to have this functionality included in PSE.
Guest over 3 years ago in Asset Framework (AF) 2 No status

Add Dismiss all completed recalculations in Analysis Management tab - Pending operations

It would be useful Dismiss all completed recalculations in Analysis Management tab > Pending operations when requesting multiple recalculations at the same time.
Guest about 1 year ago in Analytics & Calculations 0 No status

PI FrequencyGT function and PI FrequencyLT need to be added in AF analysis.

Please add PI FrequencyGT and PI FrequencyLT functions in AF analysis, like PI TimeGT and PI TimeLT, which find the frequency (number of times) within a range when an attribute value is greater or less than a given value.
Guest 7 months ago in Analytics & Calculations 0 No status