Roll back to the older legacy installer, previous to PI System 2016 R2.
The integrated installer will not perform as expected, as there is no explicit way to preconfigure the MSIs required to install the PI System.
This creates a very stressful scenario for very restricted environments. Please reach directly to me in...
Guest
over 2 years ago
in Installation
1
No status
A way to add notes to a PI tag at a certain time, with an indicator that will appear any time that tag is trended during that time period.
For example when a worn pump is replaced we see a step change in motor amperage. It would be nice if a note...
We are trying to use this perfmon counter as a diagnostic aid to catch issues with a third party interface, but it could be used with PI interfaces. We are checking to see if the point configuration for their interface matches across the four poss...
Enable suppression of certain error messages in HABConnect interface
Related to this article: https://customers.osisoft.com/s/knowledgearticle?knowledgeArticleUrl=000031389
I may have keys that are all spaces, and this may result in constant logging of the following error upon every database refresh (determined by...
Hello,
I don't see any roadmap from OSIsoft/AVEVA for the currently supported products. Looks like OSIsoft decided collect SRP for the existing OSIsoft software products and promote only the AVEVA products.
Thanks,
Subburaman Sankaran
Allow data update for future PI Points in PI OPC DA Server
When a future pi point is published in the OPC DA server current value matches PI DA current value but it does not update new events on the PI DA
You need to create another group in an OPC client or close the connection and reconnect to see new va...
Provide the user ability to select Event Frame templates during the Batch to Event Frames Migration
During the Batch to Event Frames Migration, all migrated Event Frames are created with 'Migrated' templates (i.e. PIBatchMigrated, PIUnitBatchMigrated, etc.). I would like the ability to pick and choose what templates migrated Event Frames are cre...
Guest
over 2 years ago
in Data Archive
0
No status
Optimize the storage and retrieval of digital tags
Given that the archive file format is proprietary, this suggestion is me shooting in the dark.
Disk compression compresses archive files very well, and my guess is that most of this compression occurs on the digital tags, since the number of poss...
Guest
over 2 years ago
in Data Archive
7
No status
Have an option to use step interpolation to the previous event
When the Step attribute of a PI Point is "on", PI assumes that a value is constant until the next event, which works well in most cases.
For PI Points that track rolling averages, rolling totals, real-time derivatives of totalizer tags with respe...
Guest
over 2 years ago
in Data Archive
1
No status
Change Flat Data to No Data if PI Interface to PI Server Connection is lost
Problem:
iIf PI Interface disconnected from PI Server, PI Point will show flat data until connection up not No data or Disconnected
Propose Solution:
Pl Server have ability to change flat data to no data if PI interface disconnected from PI Serve...
Guest
over 2 years ago
in Data Archive
1
No status