Move PSE Server Options from per-user registry location to shared file

Currently, the PSE Server Options are stored in the registry for each user, with default values coded into the application. This is a terrible design choice. The connection settings for an entity connecting to either a Data Archive or an Asset Fra...
Guest about 2 years ago in General 0 No status

Expose Analysis Service Evaluation Queue Count

For complex systems it is important to monitor the PI Analysis Service closely. The existing performance counters are helpful but we would really like the EvaluationQueueCount to be available as well. This would help determine if the EvaluationsTo...
Guest over 3 years ago in Analytics & Calculations 0 No status

Utilisting exisiting PI Datalink functions within Asset Framework for attributes

PI AF attributes (used for analyses) lacks the ability to filter for conditional values. (e.g. the function PIAdvCalcFilVal). Often data can be represented poorly for calculations and there isnt an easy way to filter the outliers and use that valu...
Guest over 3 years ago in Asset Framework (AF) 0 No status

Performance Tab "Jump to" Option

When trying to troubleshoot analyses and templates that may be causing poor performance on the "Management\Performance" tab, it can be tedious to locate the selected element to start determining why it's building in error count or taking a long ti...
Guest over 2 years ago in Analytics & Calculations 0 No status

Installer screen should read 'PI Data Archive Install Directory' instead of 'PI Data Archive Directory'

For an upgrade - misleading - could be interpreted as the folder where PI archives currently reside.
Guest over 3 years ago in Installation 0 No status

Add Archive Statistics to AFSDK

I would like to be able to request current Event Queue, Primary Event Queue, and Archive Events counters programmatically in order to perform my own throttling when backfilling from external systems. This becomes especially important if you also h...
Guest over 3 years ago in Data Archive 1 No status

PI Notification Send PI Vision HTML display not a screen shot

We have several reports that take advantage of collections in PI Vision. Collections let you view data across multiple assets sharing a template. Within a collection, we have several trends, which require you to scroll down. We need to send these ...
MattBa over 3 years ago in Notifications 0 No status

Event Frame Search using Attribute Value Filter should return results if the Attribute contains the specified value anytime during the duration of the Event Frame.

When specifying an Attribute Value Filter, PI System Explorer's Event Frame Search should return any Event Frame where the attribute has an event with the specified value during the duration of the event frame. Currently, the search only return...
Guest over 2 years ago in Asset Framework (AF) 2 No status

Document and have a dialouge that informs the user that Analysis backfilling does not observe compression settings.

Currently when backfilling an analysis with the PI Buffer Subsystem turned on, all values are sent to the PI Data Archive uncompressed. This is because values are perceived as out of order and these settings are not observed. This should be mentio...
Guest over 3 years ago in Help / Documentation / Videos 0 Declined

Add information about analyses are handled in derived templates and overriding templates

So there is absolutely nothing in the PSE user guide about how analysis templates are handled in derived templates. And while it appears that it is possible to override an analysis in the base template by creating one with the same name, there is ...
Guest over 3 years ago in Help / Documentation / Videos 0 No status