Skip to Main Content
AVEVA Product Feedback


ADD A NEW IDEA

All ideas

Showing 1347 of 1347

Installer screen should read 'PI Data Archive Install Directory' instead of 'PI Data Archive Directory'

For an upgrade - misleading - could be interpreted as the folder where PI archives currently reside.
Guest over 3 years ago in Installation 0 No status

Notifications: Choose Example Element/Event Frame for Testing

Just like for testing analyses, it would be helpful if I could select an example element (or historical event frame) when testing my notification. It's hard to tell if my configuration will populate correctly if values are generic/zeros. Waiting u...
Guest about 1 year ago in Notifications 0 No status

Add Archive Statistics to AFSDK

I would like to be able to request current Event Queue, Primary Event Queue, and Archive Events counters programmatically in order to perform my own throttling when backfilling from external systems. This becomes especially important if you also h...
Guest over 3 years ago in Data Archive 1 No status

Quadratic Regression

Add a quadratic regression function similar to "LinRegr". This would be helpful for trending relationships that are not linear, such as flow vs. pressure.
Guest about 1 year ago in Analytics & Calculations 0 No status

OIDC authentication with federated accounts (through CONNECT) requires too many steps

Currently, it is a 5-step process to get authenticated. After the first authentication, it is only a 3-step process, but still clunky.
Laurie Dieffenbach about 1 year ago in Security 0 No status

PI Notification Send PI Vision HTML display not a screen shot

We have several reports that take advantage of collections in PI Vision. Collections let you view data across multiple assets sharing a template. Within a collection, we have several trends, which require you to scroll down. We need to send these ...
MattBa over 3 years ago in Notifications 0 No status

Analysis timerule option: Add a possibility to make the timerule conservative. Emit calculation events only if the snapshot time of all inputs are more recent than the planned calculation time.

Now the TimeRules Natural and Periodic emit events to the Data PIPE in case NATURAL: an event is received by one of the selected inputs case PERIOD: when a certain timespan elapse.Both method doesn't take into account that some input of the analys...
Guest about 1 year ago in Analytics & Calculations 0 No status

Document and have a dialouge that informs the user that Analysis backfilling does not observe compression settings.

Currently when backfilling an analysis with the PI Buffer Subsystem turned on, all values are sent to the PI Data Archive uncompressed. This is because values are perceived as out of order and these settings are not observed. This should be mentio...
Guest over 3 years ago in Help / Documentation / Videos 0 Declined

Add information about analyses are handled in derived templates and overriding templates

So there is absolutely nothing in the PSE user guide about how analysis templates are handled in derived templates. And while it appears that it is possible to override an analysis in the base template by creating one with the same name, there is ...
Guest over 3 years ago in Help / Documentation / Videos 0 No status

Change process to release security patches

Hello, whenever Osisoft identifies security issues on PI / PI AF, they deliver fixes through the next release of these applications. This is not convenient as upgrading to a new release is a risk that we don't like to be forced to take and has a ...
Guest over 3 years ago in Security 1 No status