Skip to Main Content
AVEVA Product Feedback


ADD A NEW IDEA

All ideas

Showing 1354 of 1354

backfilling start date error

I have one specific complaint but when I’m creating/testing a new event frame it is the worst. When backfilling a single analysis, the start time and end time boxes will throw an error and not allow the you to start the backfill if at any time the...
Guest 12 months ago in Asset Framework (AF) 0 No status

Search functionality in PSE to find Analyses within hierarchy

Options to locate analyses seem absent or limited to solutions outside of PSE. It would be convenient to have a feature that lets me search for an analysis, and have it return its location in hierarchy (whether it writes to a tag or not).
Guest almost 2 years ago in Asset Framework (AF) 1 No status

Analyzes are automatically switched off by the PI Analysis Service

In the case, that the PI AF Analysis Service is overloaded, there should be the possibility that faulty analyzes are automatically switched off by the PI Analysis Service. This ensures that all other analyzes functioning correctly. The failed anal...
Guest about 3 years ago in Analytics & Calculations 0 No status

PI Asset Framework - Add string "join" function to Asset Analytics

Please add a "Join" function in Asset Analytics to combine string values in an array into one string. This would allow us to combine a varying number of outputs into one single variable that can be written to one attribute. Then, when that output ...
Guest about 2 years ago in Asset Framework (AF) 0 No status

TagTot should make use of input UOM when no output UOM is defined

TagTot will automatically account for UOM that have the time dimension as something other than per day only when the input has an assigned UOM and the function has an output UOM defined. It would be friendlier if the output UOM was defaulted based...
Guest about 1 year ago in Analytics & Calculations 0 No status

Provide a MUI Kit for the Data Archive / SMT

Provide a MUI Kit for the Data Archive / SMT
David Scott about 2 years ago in Data Archive 0 No status

Improve Search Performance when using both Attribute Name and Description

When the AFAttributeSearch(AFDatabase, String, String) AF SDK method is used, the AF Server will produce queries that may result into suboptimal SQL Server execution plans when using the default pageSize parameter for searching including attribute...
Guest about 2 years ago in Asset Framework (AF) 0 No status

Limit rate of published changes through PI Builder

A lot of PI servers we work with have a high system load. When we create, change or delete PI Points in PI Builder we have to do a few hundred points at a time and monitor the Pending Events counter from Update Subsystem on the PI server to make s...
Guest about 2 years ago in PI Builder 0 No status

Properly configure allowed Analytic / Notification host during upgrade

When upgrading Analytics or Notifications, the installer forcefully changes the allowed host parameter in the Configuration database for the application being installed. This should not happen. There should be an additional CLI parameter (and coun...
Guest about 2 years ago in Asset Framework (AF) 0 No status

Move PSE Server Options from per-user registry location to shared file

Currently, the PSE Server Options are stored in the registry for each user, with default values coded into the application. This is a terrible design choice. The connection settings for an entity connecting to either a Data Archive or an Asset Fra...
Guest about 2 years ago in General 0 No status