Installer screen should read 'PI Data Archive Install Directory' instead of 'PI Data Archive Directory'

For an upgrade - misleading - could be interpreted as the folder where PI archives currently reside.
Guest over 2 years ago in Installation 0 No status

Remove Microsoft Visual Studio 2010 Tools For Office Runtime (VSTO Runtime) from any install kits that contain PI AF Client

According to this, VSTO Runtime is included with PI AF Client for the sake of PI Builder. The installation of VSTO Runtime also causes the 32-bit and 64-bit versions of the Visual C++ 2010 Redistributable to be installed as well. However, accordin...
Guest over 1 year ago in Asset Framework (AF) 0 Declined

Add Archive Statistics to AFSDK

I would like to be able to request current Event Queue, Primary Event Queue, and Archive Events counters programmatically in order to perform my own throttling when backfilling from external systems. This becomes especially important if you also h...
Guest over 2 years ago in Data Archive 1 No status

PI Notification Send PI Vision HTML display not a screen shot

We have several reports that take advantage of collections in PI Vision. Collections let you view data across multiple assets sharing a template. Within a collection, we have several trends, which require you to scroll down. We need to send these ...
MattBa over 2 years ago in Notifications 0 No status

Add severity as a notification trigger criteria

Sometimes we have cases where we want to create the event but do not send a notification if the severity is low. I think it would be beneficial if we could add the severity as a criteria for notifications, that way we can choose at which point the...
Guest almost 2 years ago in Notifications 0 No status

Document and have a dialouge that informs the user that Analysis backfilling does not observe compression settings.

Currently when backfilling an analysis with the PI Buffer Subsystem turned on, all values are sent to the PI Data Archive uncompressed. This is because values are perceived as out of order and these settings are not observed. This should be mentio...
Guest over 2 years ago in Help / Documentation / Videos 0 Declined

Add information about analyses are handled in derived templates and overriding templates

So there is absolutely nothing in the PSE user guide about how analysis templates are handled in derived templates. And while it appears that it is possible to override an analysis in the base template by creating one with the same name, there is ...
Guest over 2 years ago in Help / Documentation / Videos 0 No status

Change process to release security patches

Hello, whenever Osisoft identifies security issues on PI / PI AF, they deliver fixes through the next release of these applications. This is not convenient as upgrading to a new release is a risk that we don't like to be forced to take and has a ...
Guest over 2 years ago in Security 1 No status

Rename or add descriptions for Read, Write, Read Data, and Write Data permissions in PI System Explorer

In PI System Explorer, the definitions of the Read, Write, Read Data, and Write Data permissions are not clear from their names. Their names are also misleading. For example, Read permission can be interpreted as "General Read", making Read appear...
Guest over 2 years ago in Security 1 Declined

Allow sorting of Database Security Identities

There should be some type of sorting feature for the Security Identities/Securities listed in the Database Security section of System Management Tools. A simple fix would be to allow us to remove an identity, re-add it and have that appear on the ...
Guest over 2 years ago in Security 0 Declined