I would like to be able to insert a new variable above or below a highlighted variable, instead of having the new variable always go to the bottom of the list. This is very problematic when needing to add a new variable to the top of the list when...
I would like to be able to do a Rollup Analysis of Booleans attributes, without casting or converting the boolean. As Rollup Functions I would suggest: Logical AND, Logical OR and maybe Count of True/False.
It can be use to create a Combined Stat...
Outputs at close available for all generation modes
‘Outputs at close’ is very powerful and flexible. It allows one to use expression analysis syntax in event frames. Unfortunately, it is only available for generation mode 'explicit trigger', but not for 'pulse', 'step', or 'step continuous'.
If y...
Follow all notifications status & be able to resend a notification
When a notification is not sent, it's very difficult to follow which notification has been sent or not. In case where the notification has'nt been sent, have the possibility to send manually the notification.
Guest
about 4 years ago
in Notifications
3
No status
Update description of existing elements and analysis when template description is updated
When a element or analysis template description is changed, descriptions of existing elements or analyses are not updated. The description is only updated when the element or analysis is created.
A customer has proposed the following options:
I...
In many UseCases we need more programability functions in PI. As example loop functions. We like the AF Framework, beacuse if you search in case of a problem you are very fast. But the functionaclity is unfortunatly not very rich.
Please integrat...
Rename overwritten archive files with new start time when using Archive_OverwriteDataOnAutoShiftFailure
When using the Tuning Parameter, "Archive_OverwriteDataOnAutoShiftFailure", the system uses the oldest registered archive as the new primary. But it keeps the name of the old archive. It would be very helpful if the archive subsystem could rename ...
kliffhopson
12 months ago
in Data Archive
0
No status
Allow AF Table to use subsecond timestamps for DateTime columns
Allow DateTime columns in AF Tables to show subseconds Events come in with very similar timstamps except subsecond level. For example 2025-01-14 03:55:01.533 XYZ and 2025-01-14 03:55:01.833 ABC but in AF Table columns subsecond is not show so both...
AVEVA Identity Manager should have a different description for button "Windows integrated login"
Although Windows AD is always a default identity provider for AIM, in certain security plans it is desired for Windows credentials not to be used by any general PI users for authentication, but instead for credentials from a different preferred id...