Properly handle Event Frame edits on Event Frames that are generated by the PI Analysis Service
Users manipulate open event frames that are generated by the PI Analysis Service. The manipulation can be:
1) Write to an attribute on the EF
2) Write an annotation
3) Acknolwedge the EF
When these manipulations are being performed the Event Fra...
Poly function should allow number attributes as coefficients
The current Poly function does not support attributes as coefficients, so we need to revert back to using Pow. This makes the Poly function of little additional benefit.
We need to be able to use any numeric attribute as input for the Poly coeffi...
I would like the ability to move searches defined on the PSE management tag from computer to computer
I have created numerous searches on the management tab of the PSE, but if changing computers or even sharing the searches between workers you currently have to recreate the searches on each computer. Not sure where these are stored currently, but ...
Ability to disable load shedding on Individual analyses
As a PI Admin I would like the ability to disable load shedding on individual analyses. This will ensure that critical analyses do not skip without having to disable load shedding at the service level and potentially impact performance.
Allow PI Builder to be used with Windows Store Application version of Excel
If Excel is installed as a Windows Store Application instead of a Desktop Application, the PI AF Client installer doesn't allow PI Builder to be installed. The reason for that is that it can't determine the Excel version through the registry.
PI...
Make Acknowledged status available within Event Frame
Since we have an EventFrame() function to pull in StartTime, EndTime, and Duration from within an event Frame, it would be useful to also be able to access whether or not the event frame was acknowledged.
Use case: If level 1 users have not ackno...
PI EFGen interface : allow configuration of events without OS-admin rights
PI EFgen interface is built in such a way that it is not possible to configure events without Windows-Admin rights on the machine hosting the interface. This is not relevant in term of security and we would like to let key-users configure events w...
Under the "Event Frame Search" option, give users more options for triggering on Attribute Values
When setting a notification's trigger criteria and specifying the "Event Frame Search" option, give the user more options for triggering on Attribute Values.
Current options: Equal, Not Equal
Suggestions: Greater Than, Less Than, Greater Than Or...
Allows to customize Rest delivery endpoint url with element informations
I would like to post notification to a custom Rest URL based on targeted element informations.
For example, If the notification is linked to an element named GR01, I would like to call :
http://127.0.0.1/services/notification/gr01
So I would lik...
Unfortunatly PI Notfication is an very old tool.
The Tool is very old and slow.
Improvements are needed.
Improvements needed:
1. Performance Update for the engineering tool in the AF is very poor
2. Functionality to send an event to an webapi is...