Skip to Main Content
AVEVA Product Feedback


ADD A NEW IDEA

All ideas

Allow AF Table to use subsecond timestamps for DateTime columns

Allow DateTime columns in AF Tables to show subseconds Events come in with very similar timstamps except subsecond level. For example 2025-01-14 03:55:01.533 XYZ and 2025-01-14 03:55:01.833 ABC but in AF Table columns subsecond is not show so both...
Guest almost 2 years ago in Asset Framework (AF) 1 No status

Rename overwritten archive files with new start time when using Archive_OverwriteDataOnAutoShiftFailure

When using the Tuning Parameter, "Archive_OverwriteDataOnAutoShiftFailure", the system uses the oldest registered archive as the new primary. But it keeps the name of the old archive. It would be very helpful if the archive subsystem could rename ...
kliffhopson about 1 year ago in Data Archive 0 No status

Attempting backfilling shows " Unknown Issue" and requires restarting the analysis service

Resolve the existing issue GetSecurityRights Throws NullReference Exception. This issue requires planning and time to resolve that can affect business processes.
Guest 4 months ago in Analytics & Calculations 0 No status

Please add product name (eg 2018 SP2) to the version information in PI SMT

You have to translate between software version (eg 3.4.445.688) and the product name (eg 2018 SP2) by searching for a document in support. It would make sense to show the product name in PI SMT alongside the software version
Guest almost 2 years ago in System Management 0 No status

Make the settings of plug-ins more accessible

In PI System Explorer, go to File → Server Properties… → Plug-Ins. If you right-click on a plug-in, you can then click on "Settings…". However, for all of the plug-ins except for 2, if you try to view their settings window, a message that says "Th...
Guest 5 months ago in Asset Framework (AF) 0 No status

Add option to clear buffer errors to the Buffering Manager

Currently users have to use the command line tools to clear buffer point errors. It would be useful and enhance O&M if these errors could be cleared directly from the UI rather than just viewed.Bonus points for allowing users to clear all, mul...
Shawn McNabb over 2 years ago in System Management 0 No status

Add Kerberos Authentication for PI Asset Analytics

Currently, PI Asset Analytics utilizes NTLM authentication. My customer's MSFT Windows Ops team does not recommend using NTLM and by default have this deactivated. Request is to add support for Kerberos authentication for PI Asset Analytics as ...
Guest about 4 years ago in Security 0 No status

High availability options with Big-IP F5 for Notifications and Analytics instead of only Windows Clustering?

We have redundant servers for AF components (Notifications & Analytics). In a virtual environment, our IT doesn't support Windows Clustering due to the way storage is implemented enterprise wide. What does it take to support F5? Our IT engin...
jagdish.konathala about 4 years ago in Analytics & Calculations 2 Declined

Version dependent analysis

It should be possible to change the used analyses dependent on the version of an element. Currently the analyses are used across all element versions. For example I want to calculate the expected output of a machine. Starting on 01-Oct the machin...
Guest about 4 years ago in Analytics & Calculations 6 Declined

Override output timestamp when the output is also input for the analysis

If the output of your analysis is also used as an input for the analysis, the option offset the output timestamp relative to the trigger time is grayed out and you see the message "Cannot override output time stamp if any output is used as an inpu...
Guest about 4 years ago in Analytics & Calculations 2 Tell us more