Skip to Main Content
AVEVA Product Feedback


ADD A NEW IDEA

All ideas

Showing 1338 of 1338

Data Collection Manager User management

We are running a central DCM Server in our site to maintain the dataflow between different UA Connectors and different DataArchive/AF pairs. We use this DCM to restart Connectors and to browse and select new Tags on a OPC UA Server. As central Ad...
Guest about 3 years ago in System Management 1 No status

Allow access to Attribute Timestamp without using Analysis

It would be very helpfull if we could access not only attribute values but also their timestamp in formulas, string builder, etc.. For example, this would help calculate staleness of a value, or it could be used to set a PI Point Attribute to show...
Guest about 3 years ago in Asset Framework (AF) 2 No status

Avoid naming SQL management scripts Go.bat

It is possible to name these files more specifically to convey what to expect when running them: Example 1: AF_SQL_295.bat Example 2: AF_SQL_290.bat Example 3: Vision_SQL_320.bat Currently a single name of Go.bat is assigned to SQL management scr...
Guest about 3 years ago in Asset Framework (AF) 0 Declined

Automatic PI Point Creation

It would be convenient if PI Points were automatically created when deploying an element based on an element template for the attribute templates that have Tag Creation set. The current approach is to right click > Create or Update Data Reference.
Guest about 3 years ago in Asset Framework (AF) 0 Declined

Allow internal AF Tables to be linked from one AF Database to another

In some scenarios, creating a linked table to an internal AF table is more appropriate than linking to an external table. For example, an internal AF table which contains a list of assets and their associated tag name may be applicable to multiple...
Guest about 3 years ago in Asset Framework (AF) 0 No status

Allow nested attribute references for String Builder Data References

As a PI System Admin, I would like to reference an attribute value as part of my attribute data references for a String Builder data reference. For example, suppose I have a parent asset 'Parent' with an attribute of 'XD5' and a child element 'Chi...
Guest about 3 years ago in Asset Framework (AF) 0 No status

Ability to move an AF element within the hierarchy in PSE by right-clicking on the element

When moving an AF element within the hierarchy in PSE using the "Shift key + Drag and Drop" approach, it can cause to create an Element reference if the release of the "Shift key" is done before dropping the element. Having the option of right-cl...
Guest about 3 years ago in Asset Framework (AF) 0 No status

Allow Analysis to use "BadVal"

We have many cases where data is showing up as "questionable" and thus cannot be used in an analysis even tho the value is still mostly good and can still be accurately used in a calculation. Being able to choose to use these "BadValues" would be ...
Guest 4 months ago in Analytics & Calculations 0 No status

Improve performance of creating large numbers of new tags

I have three large customers who have experienced PI Data Archive performance issues when large numbers of tags are being created. Specifically, record locks seem to take an extra large time (e.g., more than 15 minutes) to clear, and data updates ...
Laurie Dieffenbach 12 months ago in System Management 1 No status

Allow Federation of ClientIDs and tokens from Entra ID into AVEVA Identity Manager

For clients who previously relied on claims authentication with PI Web API, it would be useful to be able to reproduce a similar authentication flow with bearer authentication and the AVEVA Identity Manager in PI Server 2023. Currently, federation...
Guest 12 months ago in Security 1 No status