It should be possible to change the used analyses dependent on the version of an element. Currently the analyses are used across all element versions.
For example I want to calculate the expected output of a machine. Starting on 01-Oct the machin...
Override output timestamp when the output is also input for the analysis
If the output of your analysis is also used as an input for the analysis, the option offset the output timestamp relative to the trigger time is grayed out and you see the message "Cannot override output time stamp if any output is used as an inpu...
Give analyses format function the ability to format timestamp
Give analyses format function the ability to format timestamp similar to the one in the formula data reference. e.g. Format (datetime, "dd-MMM-yyyy HH: mm: ss");
Users should have flexible Analysis scheduling options, similar to the Outlook recurring meeting options.
See attached image for date-based recurrence patterns. Similar patterns for time would be helpful as well.
As is, many PI Analysis users ar...
There are no number base conversion functions available in AF Analysis. There are many situations where I need to convert numbers between different 'number bases'. I frequently work with MODBUS devices and there are many times number base conversi...
Additional documentation and examples to reference non-primary referenced Elements on Event Frames Templates
Some users asked for an enhancement of the documentation/ guide videos regarding syntax for referencing a non-primary element on a PI Point attribute from Event frame templates. The OSIsoft live guide does not provide enough information and/or exa...
Add the option to delete all event frames that reference an element when the element is deleted
When deleting an element using PI System Explorer, there should be an option to delete all event frames that reference the element. Currently when deleting an element, the delete option "Delete this object and all references to it" does not delete...
Outputs at close available for all generation modes
‘Outputs at close’ is very powerful and flexible. It allows one to use expression analysis syntax in event frames. Unfortunately, it is only available for generation mode 'explicit trigger', but not for 'pulse', 'step', or 'step continuous'.
If y...
Different email formats for event start and end conditions
There is a requirement to include different information in the email body depending on whether the notification is for the event start or end. Typically, the event start email includes the start time and start values and the event end email also i...